Neonates with respiratory distress syndrome (RDS), who are treated according to INSURE protocol; require arterial blood gas (ABG) analysis to decide on appropriate management. We conducted this study to investigate the validity of pulse oximetry instead of frequent ABG analysis in the evaluation of these patients. From a total of 193 blood samples obtained from 30 neonates <1500 grams with RDS,...

2011
Paul D. Mannheimer

Introduction Reliable and accurate pulse oximetry requires the design and operation of the entire system to function together. Contributions ranging from the sensor technology, cabling and electronics, signal processing and alarm technologies, to communicating results to caregivers through local and remote displays, are all critical and interrelated (Figure 1). Many years of experience in each ...

Journal: :international journal of pediatrics 0
nemat bilan pediatric pulmonologist, peiatric health research center, tabriz university of medical sciences, tabriz, iran. azar dastranji pediatrician, tabriz university of medical sciences, tabriz, iran. afshin behbahani ghalehgolab pediatric nephrologist, tabriz university of medical sciences, tabriz, iran.

introduction:  one ofdiagnostic criteria for acute lung injury and acute respiratory distress syndrome is  pao2/fio2 (pf) ratio 300 for ali or 200 for ards. this criteria requires invasive arterial sampling. measurement of spo2/fio2 (sf) ratio by pulseoximetry may be a reliable non invasive alternative to the pf ratio.   methods and materials: in a cross sectional study we enrolled 105 sample o...

Journal: :JAPANES JOURNAL OF MEDICAL INSTRUMENTATION 1992

Journal: :iranian journal of medical sciences 0
pedram niknafs division of neonatology, afzalipour medical center, kerman university of medical sciences, kerman, iran elahe norouzi division of neonatology, afzalipour medical center, kerman university of medical sciences, kerman, iran bahareh bahman bijari division of neonatology, afzalipour medical center, kerman university of medical sciences, kerman, iran mohammad reza baneshi research center for modeling in health, institute for future studies, kerman university of medical sciences, kerman, iran

neonates with respiratory distress syndrome (rds), who are treated according to insure protocol; require arterial blood gas (abg) analysis to decide on appropriate management. we conducted this study to investigate the validity of pulse oximetry instead of frequent abg analysis in the evaluation of these patients. from a total of 193 blood samples obtained from 30 neonates <1500 grams with rds,...

Journal: :international journal of advanced biological and biomedical research 2014
batol yarahmadi fatemeh shabkhiz jalal yarahmadi omol banin yarahmadi

main aim of this research was comparing mild swimming and recoveries jacuzzis recovery on blood lactic acid and blood pressure of swimmers. we used descriptive statistics (placebo, median, mean, variance, and standard deviation) for analyzing data in order to compare changes of saturated percentage of blood cell. we collected data from pools of mashhad and we used from 45 person for collecting ...

ژورنال: پیاورد سلامت 2008
اخگر عراقی, آریا, اخگر عراقی, شهرزاد, رحیمی فروشانی, عباس, فرزانه نژاد, احمدرضا,

Background and aim: One of the most important technological advancements for monitoring patients -- especially in anesthesia, recovery, and Intensive Care stages -- is pulse oximetry which can measure the oxygen saturation of arterial blood (spo2) and show hypoxemia before it is clinically observable. Therefore, it is necessary for the individuals who are responsible for treating and taking car...

Journal: :Indian pediatrics 2015
N B Mathur A Gupta S Kurien

OBJECTIVE To evaluate pulse oximetry for detection of congenital cyanotic heart disease in sick neonates using echocardiography as gold standard. METHODS Pulse oximetry readings were taken at admission from 950 neonates from right upper limb and either foot with infant breathing room air. Pulse oximetry was considered abnormal if oxygen saturation at room air measured <90% or difference betwe...

M. A. Khalilzadeh M. A. Younessi Heravi, S. Joharinia

Background: One of the main problems especially in operating room and monitoring devices is measurement of Blood Pressure (BP) by sphygmomanometer cuff.Objective: In this study we designed a new method to measure BP changes continuously for detecting information between cuff inflation times by using vital signals in monitoring devices. This will be achieved by extraction of the time difference ...

Journal: :Physiological measurement 2009
M P McEwen G P Bull K J Reynolds

Despite its success as a clinical monitoring tool, pulse oximetry may be improved with respect to the need for empirical calibration and the reports of biases in readings associated with peripheral vasoconstriction and haemoglobin concentration. To effect this improvement, this work aims to improve the understanding of the photoplethysmography signal-as used by pulse oximeters-and investigates ...