نتایج جستجو برای: portal dosimetry

تعداد نتایج: 40198  

2013
Yun Liang Gwe‐Ya Kim Todd Pawlicki Arno J. Mundt Loren K. Mell

The purpose of this study was to develop dosimetry verification procedures for volumetric-modulated arc therapy (VMAT)-based total marrow irradiation (TMI). The VMAT based TMI plans were generated for three patients: one child and two adults. The planning target volume (PTV) was defined as bony skeleton, from head to mid-femur, with a 3 mm margin. The plan strategy similar to published studies ...

2016
Eduardo Pardo Juan Castro Novais María Yolanda Molina López Sheila Ruiz Maqueda

Varian introduced (in 2010) the option of removing the flattening filter (FF) in their C-Arm linacs for intensity-modulated treatments. This mode, called flattening filter-free (FFF), offers the advantage of a greater dose rate. Varian's "Portal Dosimetry" is an electronic portal imager device (EPID)-based tool for IMRT verification. This tool lacks the capability of verifying flattening filter...

2013
M Oldham

A quality assurance method that utilizes 3D dosimetry and facilitates clinical interpretation Oldham Mark; Thomas Andrew; O'Daniel Jennifer; Juang Titania; Ibbott Geoffrey; Adamovics John; Kirkpatrick John P International journal of radiation oncology, biology, physics (2012), 84(2), 540-6. PURPOSE: To demonstrate a new three-dimensional (3D) quality assurance (QA) method that provides comprehe...

2013
S J Blake A L McNamara

Amorphous silicon (a-Si) electronic portal imaging devices (EPIDs) are x-ray detectors frequently used in radiotherapy imaging and dosimetry applications. EPIDs employ a copper plate and gadolinium oxysulfide phosphor screen with an array of a-Si photodiodes to indirectly detect incident radiation. In this study, a previously developed Monte Carlo (MC) model of an aSi EPID has been extended for...

2015
Ganesh Narayanasamy Travis Zalman Chul S. Ha Niko Papanikolaou Sotirios Stathakis

The purpose of this study is to evaluate the use of the Dosimetry Check system for patient-specific IMRT QA. Typical QA methods measure the dose in an array dosimeter surrounded by homogenous medium for which the treatment plan has been recomputed. With the Dosimetry Check system, fluence measurements acquired on a portal dosimeter is applied to the patient's CT scans. Instead of making dose co...

2001
Martin Lachaine Biagio Gino Fallone

During a radiation therapy treatment, many factors may influence the proper delivery of a calculated dose distribution. Some of these factors include misalignment of the treatment beam with respect to the patient, external or internal patient motion, or inaccurate positioning of beam-modifying devices.1 In order to quantify these geometric inaccuracies during treatment, a portal image is typica...

2017
Gilmer Valdes Maria F. Chan Seng Boh Lim Ryan Scheuermann Joseph O. Deasy Timothy D. Solberg

PURPOSE To validate a machine learning approach to Virtual intensity-modulated radiation therapy (IMRT) quality assurance (QA) for accurately predicting gamma passing rates using different measurement approaches at different institutions. METHODS A Virtual IMRT QA framework was previously developed using a machine learning algorithm based on 498 IMRT plans, in which QA measurements were perfo...

2017
Li-Hong Yao Liang Su Lu Liu Hai-Tao Sun Jun-Jie Wang

Background: Portal-vein stent combined with one iodine-125 (125I) seed strand has become a new treatment for portal vein tumor thrombosis. However, dosimetric aspects of this irradiation stent have not been reported. Therefore, we aimed to undertake dosimetric analyses comparing portal-vein stents combined with different numbers of 125I seed strands. Methods: A water cylinder was created by a...