نتایج جستجو برای: polymer gel dosimetry

تعداد نتایج: 201784  

2007
Jouni Uusi–Simola Sami Heikkinen Petri Kotiluoto Tom Serén Tiina Seppälä Iiro Auterinen Sauli Savolainen

Radiation sensitive polymer gels are among the most promising three-dimensional dose verification tools developed to date. Polymer gel dosimeter known by the acronym MAGIC has been tested for evaluation of its use in boron neutron capture (BNCT) dosimetry. We irradiated a large (diameter 10 cm, length 20 cm) cylindrical gel phantom in the epithermal neutron beam of the Finnish BNCT facility at ...

2017
E Maynard M Hilts

This work assesses the overall reproducibility and accuracy of an x-ray computed tomography (CT) polymer gel dosimetry (PGD) system using a N-isopropylacrylamide (NIPAM) based polymer gel and investigated what effects the use of generic, inter-batch, and intra-batch gel calibration have on dosimetric and spatial accuracy. Overall excellent spatial and dosimetric accuracy was found with this sys...

M. Allahverdi, M.H. Zahmatkesh, Mahbod Sedaghat, R. Jaberi, Sh. Akhlaghpoor,

ABSTRACTBackground: Polymer gels are an emerging new class of dosimeters which are being applied to the challenges of modern radiotherapy modalities. Research on gel dosimetry involves several scientific domains, one of which is the imaging techniques with which dose data is extracted from the dosimeters. In the current work, we present our preliminary results of investigating capability of X-r...

Journal: :iranian journal of radiation research 0
f. pake department of medical physics and biomedical engineering, faculty of medicine, tehran university of medical sciences, tehran, iran a. takavar department of medical physics and biomedical engineering, faculty of medicine, tehran university of medical sciences, tehran, iran h.a. nedaie department of medical physics and biomedical engineering, faculty of medicine, tehran university of medical sciences, tehran, iran h.r. saligheh rad department of medical physics and biomedical engineering, faculty of medicine, tehran university of medical sciences, tehran, iran e. eqlimi department of medical physics and biomedical engineering, faculty of medicine, tehran university of medical sciences, tehran, iran v. vaezzadeh department of radiotherapy oncology, cancer research centre, cancer institute, tehran university of medical sciences, tehran, iran

background:  in this study a series of basic dosimetric properties of a low-density (ld) gel dosimeter are investigated. the dose response is studied regarding to linearity, sensitivity, dose-rate and energy dependence as well as lung tissue equivalence. materials and methods: the ld gel was made by mixing the polymer gel with expanded polystyrene spheres. energy dependence was studied at two d...

Ghorban Safaeian Mohammad Hosein Bahreyni Toossi Mohammad Taghi Bahreyni Toossi, Shahram Baiani

Introduction: The purpose of this work was to study the ability of MRI normoxic polymer gel dosimetry for evaluating the dose distribution in HDR brachytherapy of esophagial cancer at Imam Reza brachytherapy center (Mashhad, Iran). Materials and Methods: Initially, 2liters of normoxic gel (MAGIC) was fabricated and then poured into 12 calibration test tubes and placed in a perspex walled phanto...

Journal: :iranian journal of radiation research 0
w. parwaie department of radiology, faculty of para-medicine, hormozgan university of medical sciences, bandar abbas, iran m. yarahmadi department of medical physics, faculty of medicine, kurdistan university of medical sciences, sanandaj, iran h.a. nedaie department of radiotherapy, cancer institute, tehran university of medical sciences, tehran, iran m.h. zahmatkesh shahid beheshti university of medical sciences, tehran, iran a.h. barati department of medical physics, faculty of medicine, kurdistan university of medical sciences, sanandaj, iran m. afkhami department of radiology, faculty of para-medicine, hormozgan university of medical sciences, bandar abbas, iran

background: accurate small radiation field dosimetry is essential in modern radiotherapy techniques such as stereotactic radiosurgery (srs) and intensity modulated radiotherapy (imrt). precise measurement of dosimetric parameters such as beam profile, percentage depth doses and output factor of these beams are complicated due to the electron disequilibrium and the steep dose gradients. in the p...

Journal: :iranian journal of radiation research 0
t. allahverdi pourfallah department of medical physics and biomedical engineering, tehran university of medical sciences, tehran, iran m. allahverdi department of medical physics and biomedical engineering, tehran university of medical sciences, tehran, iran n. riyahi alam department of medical physics and biomedical engineering, tehran university of medical sciences, tehran, iran m.r. ay research center for science and technology in medicine, tehran university of medical sciences, tehran, iran m.h. zahmatkesh novin medical radiation institute, tehran, iran

background: polymer gel dosimetry is still the only dosimetry method for direct measuring of threedimensional dose distributions. mri polymer gel dosimeters are tissue equivalent and can act as a phantom material. in this study the obtained isodose maps with pagat polymer gel dosimeter were compared to those calculated with egsnrs for singleshot irradiations of 8 and 18 mm collimators of gamma ...

2008
Louis Archambault Ghyslain Leclerc Luc Beaulieu Heather M Whitney Daniel F Gochberg E. Pappas T. G. Maris S. Manolopoulos F. Zacharopoulou A. Papadakis S. Green C. Wojnecki

Small photon fields are increasingly used in modern radiotherapy and especially in IMRT and SRS/SRT treatments. Accurate beam profile measurements of such beams are crucial for a precise and effective treatment. In this work four different dosimetric methods have been used for profile measurements of three small 6 MV circular fields having diameters of 7.5, 15.0 and 30.0 mm. A small sensitive v...

Ghorban Safaeian, Mina Nouri, Mohammad Hosein Bahreyni Toossi Mohammad Taghi Bahreyni Toossi Shahram Bayani

Introduction: The objective of this work is to study the ability of MRI normoxic polymer gel dosimetry system to be used to verify the calculated dose distribution, in a simple geometry, in clinical radiotherapy. Materials and Methods:  Initially, 2 liters of the normoxic MAGAT polymer gel was prepared and then poured into two cylindrical Perspex phantom (simu...

Journal: :Journal of Physics: Conference Series 2010

نمودار تعداد نتایج جستجو در هر سال