نتایج جستجو برای: planimeter
تعداد نتایج: 86 فیلتر نتایج به سال:
BACKGROUND Current wound assessment practices are lacking on several measures. For example, the most common method for measuring wound size is using a ruler, which has been demonstrated to be crude and inaccurate. An increase in periwound temperature is a classic sign of infection but skin temperature is not always measured during wound assessments. To address this, we have developed a smartpho...
BACKGROUND AND PURPOSE Currently, no specific method exists to measure arteriovenous malformation (AVM) nidus size, a requirement in assessing the success of treatment. Additionally, the commonly used evaluation provides only a linear one-dimensional measurement of this three-dimensional entity. The purpose of this study was to devise an improved method for measuring AVM nidus size, an irregula...
The geometry of the tracks left by a bicycle has received much attention recently [9, 10, 11, 18, 20, 27]. In this paper we discuss the connection between the motion of a bicycle and that of a curious device known as a hatchet planimeter, and we will prove a conjecture about this planimeter that was made in 1906. Bicycle. We use a very simple model of a bicycle as a moving segment in the plane....
In 18 autopsies from patients with primary pontine hemorrhage we studied the sites of bleeding, the volumes and development of hematomas and clinicopathological correlations. A modular optical electronic planimeter was introduced to measure the size of hematomas. The series of patients can be divided into 2 groups from the viewpoint of bleeding sites, their development and clinical symptomatolo...
More than 40 years ago, Magel (1970) used tracings with a compensating polar planimeter to measure propelling forces in swimming. By that time, average height of the curves was calculated in millimetres and converted to average force measures. Advances in technology, permitted picking up old methodologies and give them new features. In fact, the use of a force transducer to assess the forces ex...
• Calculation of cardiac output from dye dilution curves as described by Hamilton has been well verified.' 3 The technique of calculating the cardiac output with the use of a planimeter or replotting on log paper is tedious and-often inexact. Furthermore, the necessary long delay between the dye injection and the availability of the result has limited the use of this technique in medical resear...
This article presents a model-based segmentation method applied to 3D data acquired on sunflower plants. Our objective is the quantification of the plant growth using observations made automatically from sensors moved around plants. Here, acquisitions are made on isolated plants: a 3D point cloud is computed using Structure from Motion with RGB images acquired all around a plant. Then the propo...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید