نتایج جستجو برای: photon contamination electron beams magnetic field simulation

تعداد نتایج: 1914707  

Journal: :iranian journal of medical physics 0
mohamad javad tahmasebi-birgani department of medical physics, jundishapuruniversity of medical sciences, ahvaz, iran mohamad reza bayatiani radiotherapy and medical physics department of arak university of medical sciences&khansari hospital, arak, iran fatemeh seif radiotherapy and medical physics department of arak university of medical sciences&khansari hospital, arak, iran mansur zabihzadeh department of medical physics, jundishapuruniversity of medical sciences, ahvaz, iran hojatolah shahbazian department of medical physics, jundishapuruniversity of medical sciences, ahvaz, iran

introduction magnetic fields are capable of altering the trajectory of electron beams andcan be used in radiation therapy.theaim of this study was to produce regions with dose enhancement and reduction in the medium. materials and methods the ndfeb permanent magnets were arranged on the electron applicator in several configurations. then, after the passage of the electron beams (9 and 15 mev va...

  Introduction: This study aimed to report the measurement of photon and electron beams to configure the Analytical Anisotropic Algorithm and Electron Monte Carlo used in clinical treatment. Material and Methods: All measurements were performed in a large water phantom using a 3-dimensional scanning system (PTW, Germany). ...

2013
Mohammad Taghi Bahreyni Toossi Marziyeh Behmadi Mahdi Ghorbani Hamid Gholamhosseinian

Several investigators have pointed out that electron and neutron contamination from high-energy photon beams are clinically important. The aim of this study is to assess electron and neutron contamination production by various prostheses in a high-energy photon beam of a medical linac. A 15 MV Siemens PRIMUS linac was simulated by MCNPX Monte Carlo (MC) code and the results of percentage depth ...

Journal: :journal of biomedical physics and engineering 0
s a rahimi tarbiat modares university b hashemi tarbiat modares university s r mahdavi iran university of medical sciences

background: estimating dosimetric parameters for small fields under non-reference conditions leads to significant errors if done based on conventional protocols used for large fields in reference conditions. hence, further correction factors have been introduced to take into account the influence of spectral quality changes when various detectors are used in non-reference conditions at differen...

ژورنال: سنجش و ایمنی پرتو 2017

Recent studies suggest that relative biological damage (RBD) may change from in to out of field regions for 6 MV photon beams. In this study RBD was calculated in and out of field of 30x30 cm2 and 40x40 cm2 6 MV clinical photon beams including low energy slowing down electrons in track length estimated method. Varian 2100C/D linear accelerator was simulated using MCNPX code. Electron and photon...

Introduction: This study investigates basic dosimetric properties of unflattened 6 MV photon beam shaped by multileaf collimator and compares them with those of flattened beams.Materials and Methods: Monte Carlo simulation model using BEAM code was developed for a 6MV photon beam based on Varian Clinic 600 unique performance linac operated with and without a flattening filter in beam line. Dosi...

Journal: :international journal of advanced biological and biomedical research 2015
mahdi jahangiri payman hejazi seyed mehdi hashemi abbass haghparast bardia hajizadeh

objective: using megavoltage photons generated by medical linear accelerator is a common modality for the treatment of malignant. the crucial problem for using photon beams >8mv is the photoneutron yields that increase the risk of secondary cancer that treated with high-energy photon beams. the contaminated neutrons produced in different components of the accelerator head and rely on many param...

Abbass Haghparast Bardia Hajizadeh Mahdi Jahangiri Payman Hejazi, Seyed Mehdi Hashemi

Objective: Using Megavoltage photons generated by medical linear accelerator is a common modality for the treatment of malignant. The crucial problem for using photon beams >8MV is the photoneutron yields that increase the risk of secondary cancer that treated with high-energy photon beams. The contaminated neutrons produced in different components of the accelerator head and rely on many param...

Abbass Haghparast Bardia Hajizadeh Mahdi Jahangiri Payman Hejazi, Seyed Mehdi Hashemi

Objective: Using Megavoltage photons generated by medical linear accelerator is a common modality for the treatment of malignant. The crucial problem for using photon beams >8MV is the photoneutron yields that increase the risk of secondary cancer that treated with high-energy photon beams. The contaminated neutrons produced in different components of the accelerator head and rely on many param...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید