نتایج جستجو برای: pedicle

تعداد نتایج: 5739  

2013
Sang-Duk Yoon Jong Young Lee Seung Myung Moon Byung Moon Cho

Cervical pedicle screw has been shown to provide stronger fixation than other methods. Due to these virtue of biomechanical characteristic, pedicle screw fixation can be used in a wide range of cervical spinal disorders, and excellent clinical results have been reported. However, this procedure is technically demanding because of the great variation in pedicle dimension and angulations between ...

2012
Dae-Jean Jo Eun-Min Seo Ki-Tack Kim Sung-Min Kim Sang-Hun Lee

OBJECTIVE To present the accuracy and safety of cervical pedicle screw insertion using the technique with direct exposure of the pedicle by laminoforaminotomy. METHODS We retrospectively reviewed 12 consecutive patients. A total of 104 subaxial cervical pedicle screws in 12 patients had been inserted. We also assessed the clinical and radiological outcomes and analyzed the direction and grade...

Journal: :Acta orthopaedica Belgica 2001
U Liljenqvist L Hackenberg T Link H Halm

While the biomechanical properties of pedicle screws have proven to be superior in the lumbar spine, little is known concerning pullout strength of pedicle screws in comparison to hooks in the thoracic spine. In vitro biomechanical pullout testing was performed to evaluate the axial pullout strength of pedicle screws versus pedicle and laminar hooks in the thoracic spine with regard to surgical...

Journal: :Orthopedics 2017
Kevin Albanese Nathaniel R Ordway Stephen A Albanese William F Lavelle

Rod reduction to pedicle screws is used for a variety of spinal fixation procedures; however, it can alter the integrity of the screw-bone interface. The authors investigated the effect of pedicle fill (ratio of pedicle screw diameter to pedicle diameter) on the strength of the screw-bone interface after simulated rod reduction on 17 vertebrae (3 thoracolumbar spine specimens). Pedicle diameter...

2017
Hongwei Wang Yiwen Zhao Zhongjun Mo Jianda Han Yu Chen Hailong Yu Qi Wang Jun Liu Changqing Li Yue Zhou Liangbi Xiang

OBJECTIVES No studies have compared monoaxial and polyaxial pedicle screws with regard to the von Mises stress of the instrumentation, intradiscal pressures of the adjacent segment and adjacent segment degeneration. METHODS Short-segment monoaxial/polyaxial pedicle screw fixation techniques were compared using finite element methods, and the redistributed T11-L1 segment range of motion, large...

2014
Risheng Xu Mohamad Bydon Mohamed Macki Stephen M. Belkoff Evan R. Langdale Kelly McGovern Jean-Paul Wolinsky Ziya L. Gokalsan Ali Bydon

BACKGROUND Posterior, atlantoaxial (AA) fusions of the cervical spine may include either standard (26 mm) or short (16 mm) C2 pedicle screws. This manuscript focused on an in vitro biomechanical comparison of standard versus short C2 pedicle screws to perform posterior C1-C2 AA fusions. METHODS Twelve human cadaveric spines underwent C1 lateral mass screw and standard C2 pedicle screw (n = 6)...

2017
Xingang Cui Guodong Wang

Pedicle screws are widely used in spinal surgeries, but it remains technically demanding to place. There are numerous studies on the anatomy of pedicle; however, there is very little insight on the relationship between the pedicle and the spinous process, which is an important part of the spinal posterior column.The aim of the study was to investigate the radiographic anatomical relationship be...

2017
Thibaut Cachon Paul Pillard Thierry Odent Claude Carozzo Eric Viguier

The pig spine is widely used as a large animal model for preclinical research in human medicine to test new spinal implants and surgical procedures. Among them, pedicle screw is one of the most common method of fixation of those implants. However, the pedicle of the porcine vertebra is not as well defined and not as large as the pedicle of the human vertebra. Therefore, the position of the scre...

Journal: :Clinical biomechanics 2016
Kingsley R Chin Anna G U Newcomb Marco T Reis Phillip M Reyes Grace A Hickam Josue Gabriel Fabio J R Pencle Roger D Sung Neil R Crawford

BACKGROUND The use of pedicle screws is the gold standard for supplemental posterior fixation in lateral interbody fusion. Information about the performance of transfacet pedicle screws compared to standard pedicle screws and rods in the upper lumbar spine with or without a lateral interbody fusion device in place is limited. METHODS Fifteen fresh frozen human cadaveric lumbar spine segments ...

Journal: :Orthopedics 2012
Scott D Hodges Jason C Eck Danette Newton

The incidence of pedicle screw breech varies based on anatomic location, body habitus, surgeon experience, spinal deformity, and surgical technique. Pedicle breeches have been reported to occur in up to 40% of screws. The purpose of this retrospective study was to compare the rates of revision of pedicle screw placement when using intraoperative C-arm vs O-arm (Medtronic, Memphis, Tennessee) as...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید