Journal: :International Journal of Radiation Oncology*Biology*Physics 2020

2012
Hidetaka Arimura Wataru Itano Yoshiyuki Shioyama Norimasa Matsushita Taiki Magome Tadamasa Yoshitake Shigeo Anai Katsumasa Nakamura Satoshi Yoshidome Akihiko Yamagami Hiroshi Honda Masafumi Ohki Fukai Toyofuku Hideki Hirata

We have developed a computerized method for estimating patient setup errors in portal images based on localized pelvic templates for prostate cancer radiotherapy. The patient setup errors were estimated based on a template-matching technique that compared the portal image and a localized pelvic template image with a clinical target volume produced from a digitally reconstructed radiography (DRR...

2012
Chengyu Shi Adam Tazi Deborah Xiangdong Fang Christopher Iannuzzi

Novalis Tx ExacTrac X-ray system has the 6D adjustment ability for patient setup. Limited studies exist about the setup uncertainty with ExacTrac X-ray system for IMRT prostate treatment with fiducial markers implanted. The purpose of this study is to investigate the marker-based prostate IMRT treatment setup uncertainty using ExacTrac 6D IGRT ability for patient setup. Forty-three patients wit...

2012
Te-yu Chyou Juergen Meyer

An approach to quantitatively determine patient surface contours as part of an augmented reality (AR) system for patient position and posture correction was developed. Quantitative evaluation of the accuracy of patient positioning and posture correction requires the knowledge of coordinates of the patient contour. The system developed uses the surface contours from the planning CT data as the r...

2010
Imad Ali Jesse Tubbs Kerry Hibbitts Ozer Algan Spencer Thompson Terence Herman Salahuddin Ahmad

The purpose of this study was to evaluate setup accuracy and quantify random and systematic errors of the BrainLAB stereotactic immobilization mask and localization system using kV on-board imaging. Nine patients were simulated and set up with the BrainLAB stereotactic head immobilization mask and localizer to be treated for brain lesions using single and hypofractions. Orthogonal pairs of proj...

M.J. Kim, M.Y. Lee, S.H. Park, S.R. Lee, T.S. Suh,

Background: The dose-related effects of patient setup errors on bio-physical indices were evaluated for the conventional wedge (CW) and field-in-field (FIF) whole breast irradiation techniques (WBI). Materials and Methods: The treatment plans of 10 patients receiving left WBI were retrospectively selected for evaluation. The bio-physical effects of dose variations were evaluated by shifting the...