نتایج جستجو برای: pagat gel

تعداد نتایج: 105062  

2017
Yi Du Gongyi Yu Xincheng Xiang A Asena S T Smith T Kairn S B Crowe

This study demonstrates the degradation in image quality, and subsequent dose evaluation inaccuracies, that are encountered when an optical-CT system reconstructs an image slice of a gel dosimeter containing an opaque implant, and evaluates the feasibility of a simple correction method to improve the accuracy of radiotherapy dose distribution measurements under these circumstances. MATLAB was u...

2010
T. Allahverdi Pourfallah M. Allahverdi N. Riyahi Alam M. R. Ay M. H. Zahmatkesh

*Corresponding author: Dr. Tayyeb Allahverdi Pourfallah, Department of Medical Physics and Biomedical Engineering, Tehran University of Medical Sciences, Tehran, Iran. Fax: +98 21 88973653 E-mail: [email protected] Background: Polymer gel dosimetry is still the only dosimetry method for direct measuring of threedimensional dose distributions. MRI Polymer gel dosimeters are tissue equi...

2012
Tayeb Allahverdi Pourfallah Mahmoud Allahverdi Mohammad Hasan Zahmatkesh

Introduction Polymer gel dosimeters offer a practical solution to 3D dose verification for conventional radiotherapy as well as intensity-modulated and stereotactic radiotherapy. In this study, EGSnrc calculated and PAGAT polymer gel dosimeter measured dose profiles from single shot irradiation with 18 mm collimator of Gamma Knife in homogeneous and inhomogeneous phantoms were compared with eac...

Mahmoud Allahverdi Mohammad Hasan Zahmatkesh Tayeb Allahverdi Pourfallah,

Introduction Polymer gel dosimeters offer a practical solution to 3D dose verification for conventional radiotherapy as well as intensity-modulated and stereotactic radiotherapy. In this study, EGSnrc calculated and PAGAT polymer gel dosimeter measured dose profiles from single shot irradiation with 18 mm collimator of Gamma Knife in homogeneous and inhomogeneous phantoms were compared with eac...

Journal: :Japanese Journal of Radiological Technology 2021

Purpose In our proton beam therapy center, we use imaging plates (IP) for dose verification of field matching in irradiation (called patch-field technique). this study, a polymer gel dosimeter, which can perform three- dimensional distribution measurement, was used as new tool the patch method corresponding to rectangular irradiation. Method The results measurements PAGAT dosimeter irradiate tw...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید