ژورنال: بینا 2019
, , Azimi, A., Bahrami, M., Momeni, H., Sedaghat , MR., Tabesh, H.,

Purpose: To compare the central corneal thickness measured through Pentacam, OCTCasia2, and Orbscan IIz in normal individuals. Methods: In this cross sectional comparative study, the researcher investigated the eyes of 70 normal candidates (140 eyes) with the mean age of 31.42 ± 7.70, referring to Dr. Sedaghat eye clinic for refractive surgery. For each person, Central Corneal Thickness (CCT) w...

2017
Mahmoud Jabbarvand Farshad Askarizadeh Mohamad Reza Sedaghat Hadi Ghadimi Bahram Khosravi Mohammad Aghazadeh Amiri Foroozan Narooie-Noori

PURPOSE The aim of this study was to determine the agreement between Pentacam HR (Scheimpflug imaging, Oculus) and Orbscan II (scanning slit topography, Bausch and Lomb) in measuring corneal parameters after photorefractive keratectomy (PRK) for hyperopia. METHODS In this prospective cross-sectional study, 38 hyperopic eyes undergoing PRK were examined before refractive surgery and 8 to 10 mo...

2015
Mohammad Mehdi Sadoughi Bahram Einollahi Neda Einollahi Javad Rezaei Danial Roshandel Sepehr Feizi

PURPOSE To compare ultrasound pachymetry and Orbscan II for measurement of central corneal thickness (CCT) in normal eyes. METHODS The current study was performed at Labbafinejad Medical Center (LMC), Tehran, Iran. Three hundred eyes from 150 healthy individuals referred for keratorefractive surgery were assessed first by Orbscan II and then by ultrasound pachymetry, and CCT values were recor...

2015
Wassia A Khaja Sandeep Grover Amy T Kelmenson Lee R Ferguson Kumar Sambhav Kakarla V Chalam

BACKGROUND Central corneal thickness (CCT) can be measured by using contact and non-contact methods. Ultrasound pachymetry (US pachymetry) is a contact method for measuring CCT and is perhaps the most commonly used method. However, non-contact methods like scanning slit topography (Orbscan II), slit-lamp optical coherence tomography (SL-OCT), and specular microscopy are also used. Not many stud...

Journal: :Journal of refractive surgery 2007
Hikmet Basmak Afsun Sahin Nilgun Yildirim Thanos D Papakostas A John Kanellopoulos

PURPOSE To obtain normative values of angle kappa in a normal population by synoptophore and Orbscan II and to compare the reliability of these devices. METHODS Three hundred consecutive healthy individuals were enrolled in the study. A complete orthoptic and ophthalmologic examination was performed. Synoptophore and Orbscan II corneal topography were used to measure angle kappa. To evaluate ...

Journal: :International journal of ophthalmology 2015
Hai-Xia Zhao Li Zhang Wen-Ying Guan

AIM To investigate the differences in central corneal thickness (CCT) and curvature in myopic patients with different genders between Mongolian and Han nationalities in the Inner Mongolia region. METHODS Patients with myopia, among whom 122 cases (244 eyes) were Mongolian and 150 cases (300 eyes) were Han, were selected. Pentacam was used to measure the corneal curvature, whereas CCT was dete...

2015
Kaevalin Lekhanont Manachai Nonpassopon Khemruetai Wannarosapark Varintorn Chuckpaiwong

The purpose of this study was to investigate the agreement between the clinical history method (CHM), Orbscan IIz, and Pentacam in estimating corneal power after myopic excimer laser surgery. Fifty five patients who had myopic LASIK/PRK were recruited into this study. One eye of each patient was randomly selected by a computer-generated process. At 6 months after surgery, postoperative corneal ...

Journal: :Chang Gung medical journal 2012
Tsung-Ho Ou Ing-Chou Lai Mei-Ching Teng

BACKGROUND Intraocular pressure (IOP) measurements are affected by the central cornea thickness (CCT). The conventional method for CCT measurement is ultrasonic pachymetry. However, noncontact procedures lower the risk of infection and corneal damage. In this study, we compared the CCT measured by Orbscan II, SP3000P, and ultrasonic pachymetry in patients with glaucoma or glaucoma suspect. ME...

Journal: :Acta ophthalmologica 2009
Canan Asli Utine Feyza Altin Hanefi Cakir Irfan Perente

PURPOSE This study determined to assess the degree of agreement between anterior chamber depth (ACD) measurements obtained using three different devices and to analyse the relationship between ACD and spherical equivalent (SE) refraction. METHODS In this cross-sectional study, 42 eyes of 42 patients with a mean SE of - 4.69 +/- 4.61 D (range 0.00 D to - 14.88 D) were analysed. Measurements of...

Journal: :Journal of cataract and refractive surgery 2007
Thomas Ho Arthur C K Cheng Srinivas K Rao Silvania Lau Chris K S Leung Dennis S C Lam

PURPOSE To compare corneal pachymetry assessment using 4 measurement methods in eyes after laser in situ keratomileusis (LASIK) for myopia. SETTING Department of Ophthalmology & Visual Sciences, The Chinese University of Hong Kong, Hong Kong Eye Hospital, Hong Kong SAR. METHODS Fifty-two consecutive patients (103 eyes) who had LASIK for the correction of myopia had Orbscan II (Bausch & Lomb...