نتایج جستجو برای: multiple tube fermentation mtf
تعداد نتایج: 882939 فیلتر نتایج به سال:
تابع انتقال اپتیکی و اندازه آن تابع انتقال مدولاسیون (mtf) یک فاکتور بسیار مهم برای ارزیابی کیفیت عملکرد یک سیستم تصویر ساز است. نمودار mtf، تفکیک پذیری سیستم را بیان می کند. روش های بسیاری برای اندازه گیری mtf سیستم تصویربردار از جمله دوربین ccd ارائه شده است. از مهمترین مشکلات اکثر این روش ها، وابستگی mtf به مکان و موقعیت قرار گیری شئ نسبت به آرایه ccd است. در این پایان نامه با بررسی تجربی و ...
Background & Aims: Spatial resolution is one of the important features of evaluating the function of nuclear medicine imaging systems. The aim of this study was evaluating the capability of the spatial resolution in images of nuclear medicine planar by calculating the modulation transfer function (MTF). Materials & Methods: Nuclear medicine imaging of capillary tube with activity 1 mCi was per...
A one-tube test for distinguishing oxidation from fermentation in the metabolism of carbohydrates was examined on 1,200 gram-negative bacilli. There was a 100% correlation between the one-tube method and the standard two-tube procedure.
The modulation transfer function (MTF) and the noise power spectrum (NPS) are widely recognized as the most relevant metrics of resolution and noise performance in radiographic imaging. These quantities have commonly been measured using various techniques, the specifics of which can have a bearing on the accuracy of the results. As a part of a study aimed at comparing the relative performance o...
purpose: to assess the optical effect of the technis-z9000 iol decentration by lio-brennan mathematic-optical eye model. methods: the phantom with real eye parameters (lio-brennas) was used for iol technis-z9000 modeling with zemax code. modulation transfer function (mtf) and mtf contrast that represent the ratio of the image data to total object data in optical system were used for analysis. r...
Introduction: One of the main steps in the optimization process in diagnostic imaging is the quality control of radiology devices. The usual method of CT scan calibration is used of a phantom. The phantom created a certain weakening for the radiation through which it passes. One of the most suitable methods for quantitative analysis of the resolution and contrast in CT scan im...
Should computer-based study tasks use multiple-choice or constructed-response question formats? It was hypothesized that a constructed-response study task (CR) with feedback would be superior to multiple-choice study tasks that allowed either single or multiple tries (STF and MTF). Two additional recognition study task treatments were included that required an overt constructed response after f...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید