نتایج جستجو برای: modular stem
تعداد نتایج: 323525 فیلتر نتایج به سال:
We present the case of a 46-year-old woman who underwent revision surgery approximately 4 years after total hip arthroplasty because of a fracture of the modular neck of a MODULUS femoral stem. The fractured surfaces of the retrieved implant were inspected using optical and scanning electron microscopy. Three-dimensional finite element analysis was also performed to identify the stresses that m...
There is an increasing trend towards cementless modular femoral prostheses for revision hip replacement surgery, especially in patients with severe proximal femoral bone defects. However, for minor femoral bone defects, the benefit of cementless modular is not clear. We designed a retrospective cross-sectional study to compare outcomes of the two femoral implant designs. There were no significa...
Modularity in total hip arthroplasty provides multiple benefits to the surgeon in restoring the appropriate alignment and position to a previously damaged hip joint. The vast majority of modern implants incorporate modularity into their design with some implants having multiple modular interfaces. There is the potential for failure at modular junctions because of fretting and crevice corrosion ...
In this paper, we prove the existence and uniqueness of fixed points for cyclic (α,β)-admissible type F-contraction and F−weak contraction under the setting of modular spaces, where the modular is convex and satisfying the ∆2-condition. Later, we prove some periodic point results for self-mappings on a modular space. We also give some examples to s...
Cementless modular stemwas designed to allow the surgeon to independently match the anatomy of the metaphyseal and diaphyseal regions of the femoral canal of an individual patient.1 S-ROM stem (DePuy/Johnson & Johnson), which has a hollow proximal sleeve and separate cylindrical core, was introduced in 1984. So far, long-term results of this prosthesis have been excellent in osteoarthritis, dev...
BACKGROUND The Rejuvenate modular-neck stem implant (Stryker Orthopaedics, Mahwah, New Jersey) was recently recalled due to corrosion at the femoral neck-stem junction. The purpose of this study was to investigate the rate of corrosion-related failure and survivorship of this implant and analyze the correlation of implant and patient factors with serum metal ion levels and revisions. METHODS ...
PURPOSE To assess the treatment outcome of revision hip arthroplasty for Vancouver type B3 periprosthetic femoral fractures using a modular distally cemented stem. METHODS 22 men and 14 women (37 hips) aged 66 to 79 (mean, 70) years underwent revision hip arthroplasty for Vancouver type B3 periprosthetic femoral fractures. The indication for surgery was periprosthetic fracture with stem loose...
PURPOSE To assess the medium-term outcome of titanium uncemented modular tapered stems in revision total hip arthroplasty (THA). METHODS A questionnaire was mailed to 421 patients who underwent revision THA using a titanium uncemented modular tapered stem. 66 of whom underwent re-revision THA. The questionnaire was composed to reveal the Charnley classification, the modified 12-item Oxford hi...
PURPOSE The purpose of this study was to evaluate the clinical and radiological results of total hip arthroplasty using a proximal modular femoral stem in patients who had secondary coxarthrosis associated with a dysplastic hip. MATERIALS AND METHODS Forty-two patients (45 hips) with secondary coxarthrosis were evaluated after undergoing primary total hip arthroplasty using an S-ROM proximal ...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید