نتایج جستجو برای: mo rh target filter mammograms

تعداد نتایج: 562073  

2001
J. G. Che K. M. Zhang X. D. Xie

Using local density functional calculations, we studied the morphological changes of Mo(1 1 1) and W(1 1 1) upon the adsorption of an ultrathin ®lm of Rh. The unusual relaxations induced by Rh on Mo(1 1 1) and W(1 1 1) surfaces should be caused by competing several factors such as Smoluchowski smoothing e€ect, change of atomic interactions, and charge transfer between overlayer and substrate. I...

Alireza Karimian, Hajar Moradmand Mehri Sirous Saeed Setayeshi

Introduction Breast cancer is one of the most common types of cancer among women.  Early detection of breast cancer is the key to reducing the associated mortality rate. The presence of microcalcifications clusters (MCCs) is one of the earliest signs of breast cancer. Due to poor imaging contrast of mammograms and noise contamination, radiologists may overlook some diagnostic signs, specially t...

2004
Ann-Katherine Carton Hilde Bosmans Dirk Vandenbroucke Chantal Van Ongeval Geert Souverijns Frank Rogge Guy Marchal

The purpose of this study is to describe a method that allows the calculation of a contrast-detail curve for a particular system configuration using simulated micro calcifications into clinical mammograms. We made use of simulated templates of micro calcifications and adjusted their x-ray transmission coefficients and resolution to the properties of the mammographic system under consideration (...

2015
Michiharu Sekimoto Yoh Katoh Tsuguhisa Katoh

A wide variety of existing combinations of target and filter materials (target/filter combinations) are used in mammography equipment. The patient dose depends on the X-ray quality that is derived from the target/filter combination, and a calibration of the dosimeter that is used in the measurement that corresponds to the specific target/filter combination is necessary. However, dosimeters in m...

Journal: :Physics in medicine and biology 2006
J Zoetelief W J H Veldkamp M A O Thijssen J T M Jansen

The nationwide breast cancer screening programme using mammography has been in full operation in The Netherlands since 1997. There is concern that the mean glandular doses due to mammography might be differing between different regions of the country due to differences in glandularity and compressed breast thickness. To investigate regional differences, glandularity, compressed breast thickness...

1999
D. Y. HUANG P. JIANG J. G. CHE K. M. ZHANG X. D. XIE

By using first principles total energy calculations, the surface energies of (100), (110), (111) and (211) surfaces of Mo before and after adsorbing ultrathin films of Rh have been presented. The results show that in the case of clean Mo surfaces Mo(111) is stable against faceting to Mo(211), Mo(110) and Mo(100), while after adsorbing one physical monolayer of Rh, the surface energies of all th...

Journal: :iranian journal of medical physics 0
alireza karimian department of biomedical engineering, faculty of engineering, university of isfahan, isfahan, iran

introduction breast cancer is one of the most common types of cancer among women.  early detection of breast cancer is the key to reducing the associated mortality rate. the presence of microcalcifications clusters (mccs) is one of the earliest signs of breast cancer. due to poor imaging contrast of mammograms and noise contamination, radiologists may overlook some diagnostic signs, specially t...

سمیرا رازقندی علی اصغر مولوی,

ماموگرافی با اشعه x یکی از روش‌های پر‌کاربرد در تشخیص سرطان پستان می‌باشد. به دلیل حساسیت بافت پستان، میزان دُز دریافتی بیمار در ماموگرافی اهمیت ویژه‌ای دارد. هدف از مطالعه حاضر، بررسی عوامل موثر در میزان دُز جذبی و مقایسه میزان دُز دریافتی برای شرایطی که دستگاه ماموگرافی شامل ترکیب هدف-فیلتر Mo-Moیا W-Rh ‌باشد. در این پژوهش، به کمک کد MCNPX، ساختار تیوپ اشعه x دستگاه ماموگرافی شبیه سازی شده و طیف...

پایان نامه :وزارت علوم، تحقیقات و فناوری - دانشگاه تفرش - دانشکده علوم پایه 1389

در این تحقیق، از کد مونت کارلو mcnp4c به منظور شبیه سازی طیف اشعه x در رادیولوژی تشخیصی و ماموگرافی استفاده شده است. اشکال هندسی مختلفی به صورت یک طرفه، مخروطی و دوار و با زوایای متفاوت برای آند در نظر گرفته شده و ترکیبات مختلف هدف/ فیلتر به منظور ارزیابی اثر ولتاژ لوله، ماده هدف و ضخامت فیلتر روی طیف اشعه x، در محدوده انرژی ماموگرافی، رادیولوژی تشخیصی و دندان پزشکی شبیه سازی می گردد. طیف اشعه ...

Journal: :Journal of the American Chemical Society 2010
Richard H Taylor Stefano Curtarolo Gus L W Hart

The binary A(8)B phase (prototype Pt(8)Ti) has been experimentally observed in 11 systems. A high-throughput search over all the binary transition intermetallics, however, reveals 59 occurrences of the A(8)B phase: Au(8)Zn(dagger), Cd(8)Sc(dagger), Cu(8)Ni(dagger), Cu(8)Zn(dagger), Hg(8)La, Ir(8)Os(dagger), Ir(8)Re, Ir(8)Ru(dagger), Ir(8)Tc, Ir(8)W(dagger), Nb(8)Os(dagger), Nb(8)Rh(dagger), Nb(...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید