نتایج جستجو برای: mipo

تعداد نتایج: 146  

Journal: :Injury 2005
T Apivatthakakul O Arpornchayanon S Bavornratanavech

Minimally Invasive Plate Osteosynthesis (MIPO) has gained popularity with satisfactory clinical outcomes in the treatment of long bone fractures. MIPO for humeral shaft fractures, however, could be a surgically dangerous procedure because of the risk of radial nerve injury. An anatomical study was performed to evaluate the feasibility of MIPO for the humeral shaft fractures, and to study the re...

Journal: :Veterinary and comparative orthopaedics and traumatology : V.C.O.T 2009
C C Hudson A Pozzi D D Lewis

Bone plating has been used as a method of fracture management for many years. Recently, a trend toward the use of fracture fixation techniques which preserve the local fracture environment, known as biological osteosynthesis, has evolved. This trend has resulted in the development of a less traumatic method of bone plating referred to as minimally invasive plate osteosynthesis (MIPO), or percut...

Journal: :Malaysian orthopaedic journal 2012
Suman K Shrestha Pramod Devkota Laxmi P Mainali

ABSTRACT BACKGROUND Minimally invasive internal fixation is also called "biological internal fixation". This concept is used widely in the treatment of various fractures but to date, there have been no report about such application in the repair of isolated ulnar bone fractures. METHODS Eleven patients with fracture of isolated ulnar bone (four AO type 22A11 and seven AO type 22A12), mean ...

2016
Prasanta Kumar Saha

Background: Treatment of humeral shaft fractures continues to evolve as advances are made in both non-operative and operative management. The encouraging results that have been reported with recent advances in internal fixation techniques and instrumentation. The controversy still exist between plating and intramedullary nailing. MIPO (Minimal invasive plate osteosynthesis) has emerged as a new...

2016
Bin-feng Yu Liang-le Liu Guo-jing Yang Lei Zhang Xi-peng Lin

BACKGROUND The objective of this meta-analysis was to compare the efficacy and safety of minimally invasive plate osteosynthesis (MIPO) and conventional plate osteosynthesis (CPO) for humeral shaft fracture. METHODS Potential academic articles were identified from the Cochrane Library, Medline (1966-2016.3), PubMed (1966-2016.3), Embase (1980-2016.3), and ScienceDirect (1966-2016.3). Gray stu...

Journal: :Journal of orthopaedic trauma 2016
Gareth Davies Gerald Yeo Mahendrakumar Meta David Miller Erik Hohmann Kevin Tetsworth

OBJECTIVES To compare the risk of major complications after either minimally invasive plate osteosynthesis (MIPO) or intramedullary nailing (IMN) of humeral shaft fractures. DESIGN Retrospective, case-match controlled study. SETTING A major metropolitan tertiary referral trauma center in Australia. PATIENTS Thirty patients with fractures of the humeral shaft. INTERVENTION Either MIPO or...

2017
Akram A Saji Ranjan Kumar Gupta Ranjan Kumar Gopikishan Lohiya

Introduction: Tibia is one of the most commonly fractured long bone of the body. Distal tibia fractures are primarily located within a square based on the width of the distal tibia. Treatment of distal tibia fracture is challenging because of its unique anatomical characteristics of subcutaneous location with precarious blood supply and proximity to the ankle joint. Minimally invasive plate ost...

2012
Joon-Woo Kim Chang-Wug Oh Won-Ju Jung Ji-Soo Kim

BACKGROUND Relatively few studies have addressed plate osteosynthesis for open proximal tibial fractures by now. The purpose of this study was to assess the results of minimally invasive plate osteosynthesis (MIPO) for open fractures of the proximal tibia. METHODS Thirty-four patients with an open proximal tibial fracture were treated by MIPO. Thirty of these, who followed for over 1 year, co...

Journal: :Veterinary and Comparative Orthopaedics and Traumatology 2022

Introduction: Simple fractures, potentially high-strain are classically treated through anatomical reconstruction and rigid fixation, using an open reduction approach. This study aimed to evaluate the bridge plating minimally invasive plate osteosynthesis (MIPO) of simple tibial fractures. Our hypothesis was that fixation these fractures MIPO would result in early bone healing with low complica...

Journal: :trauma monthly 0
ali akbar esmailiejah akhtar orthopedic hospital, shahid beheshti university of medical sciences, tehran, ir iran mohammad reza abbasian akhtar orthopedic hospital, shahid beheshti university of medical sciences, tehran, ir iran; akhtar orthopedic hospital, shahid beheshti university of medical sciences, tehran, ir iran. tel: +98-9121831752, fax: +98-2122606614 farshad safdari orthopedics research center, akhtar hospital, shahid beheshti university of medical sciences, tehran, ir iran keyqobad ashoori orthopedics research center, akhtar hospital, shahid beheshti university of medical sciences, tehran, ir iran

conclusions due to the shorter :union: time, to some extent less complication rate and comparable functional and clinical results, the authors recommend to use the mipo technique in treating the mid-distal humeral shaft fracture. results the median of :union: time was shorter in the mipo group (4 months versus 5 months). the time of surgery and functional outcomes based on the ucla and meps sco...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید