نتایج جستجو برای: magic gel dosimeter

تعداد نتایج: 117344  

اربابی, عظیم, بلوری, بهرام, ندایی, حسن, قهرمان اصل, روح اله,

  Background & Aim: Nowadays, radiosensitive polymer gels are used as a reliable dosimetry tool for verification of 3D dose distributions. Polymer gel dosimeters consist of an aqueous mixture of monomers and a gelling agent, which after irradiation, 3D dose distribution is acquired by using imaging techniques. The aim of this study is to evaluate the application and capability of normoxic polym...

A.A. Mahmoud, A.A. Rahman, I.S. Mustafa, N.N.A Razak, N.Z. Yahaya, S. Kandaiya,

Background: An effective polymer gel dosimeter can be fabricated by varying the composition of its chemical components. Materials and Methods: The MAGAT gel dosimeter formulations that used different compositions of Methacrylic acid (MAA) and gelatin were extensively investigated in the present study according to the R2–dose response and R2–dose sensitivity. The irradiation of M...

A.H. Barati, H.A. Nedaie, M. Afkhami, M. Yarahmadi, M.H. Zahmatkesh, W. Parwaie,

Background: Accurate small radiation field dosimetry is essential in modern radiotherapy techniques such as stereotactic radiosurgery (SRS) and intensity modulated radiotherapy (IMRT). Precise measurement of dosimetric parameters such as beam profile, percentage depth doses and output factor of these beams are complicated due to the electron disequilibrium and the steep dose gradients. In the p...

2017
Heather M Whitney Daniel F Gochberg C Waldenberg A Karlsson Hauer

The normoxic polymer gel dosimeter based on N-isopropyl acrylamide (NiPAM) is a promising full 3D-dosimeter with high spatial resolution and near tissue equivalency. NiPAM gel samples were irradiated to different doses using a linear accelerator. The absorbed dose was evaluated using MRI and statistical significance of the analysed data was calculated. The analysis was carried out using an in-h...

Journal: Nanomedicine Journal 2019

Objective(s): Normoxic MAGIC-f polymer gels are established dosimeters used for three dimensional dose quantifications in radiotherapy. Nanoparticles with high atomic number such as gold are novel radiosensitizers used to enhance doses delivered to tumors. The aim of this study was to investigate the effect of gold nanoparticles (GNPs) in enhancing percentage depth doses (PDDs) within the MAGIC...

Bijan Hashemi, Hossein khosravi Seyed Rabi Mahdavi

Introduction: Normoxic MAGIC-f polymer gels are established dosimeters used for three dimensional dos uantifications in radiotherapy. The high atomic number nanoparticles such as gold are nov adiosensitizers used to enhance doses delivered to tumors. The aim of this study was t vestigate the effect of gold nanoparticles (GNPs) in enhancing percentage depth doses (PDD ithin the...

Journal: :iranian journal of medical physics 0
bakhtiar azadbakht instructor, medical radiation engineering dept, faculty of engineering, borujerd islamic azad university, borujerd, iran. *, mohammad hassan zahmatkesh associate professor, shahid beheshti university, evin, tehran, iran kamal haddad associate professor, nuclear engineering dept, faculty of engineering, shiraz university, shiraz, iran. saeid bagheri m.sc. in medical physics, shahid beheshti university, tehran, iran

introduction: the pagat polymer gel dosimeter melts at 30 ˚c and even at room temperature during the summer, so it needs to be kept in a cool place such as a refrigerator. to increase the stability of the pagat gel, different amounts of agarose were added to the pagat gel composition and the pagata gel was manufactured. material and methods: the pagata gel vials were irradiated using a co-60 ma...

Seyed Mohammad Mahdi Abtahi Vahid Anaraki

Introduction: Three physical conditions caused an external beam designated as a small field. The first is the loss of lateral charged particle equilibrium. The second is the effect of collimators on the primary photon source occlusion. The third condition is the size of the detector which is large compared to the field size. The most obvious perturbation effects in last condit...

Journal: :iranian journal of radiation research 0
k. adinehvand borujerd islamic azad university, borujerd, iran m.h. zahmatkesh novin radiation medicine institute, tehran, iran m.r aghamiri division of radiation medicine, shahid beheshti university, tehran, iran sh. akhlaghpour department of radiology, tehran university of medical sciences, tehran, iran s. bagheri novin radiation medicine institute, tehran, iran

background: the purpose of this study was to evaluate the dependency of magica polymer gel dosimeter response (r2) on different electron energies as well as on different mean dose rate for a standard clinically used linear accelerator. materials and methods: the sensitivity of the dosimeter was represented by the slope of calibration curve in the linear region measured for each modality. a cali...

Journal: :journal of medical signals and sensors 0
seyed salman zakariaee mikaeil molazadeh abbas takavar alireza shirazi asghar mesbahi ahad zeinali

in radiation cancer treatments, the most of the side effects could be minimized using a proper dosimeter. gel dosimeter is the only three‑dimensional dosimeter and magnetic resonance imaging (mri) is the gold standard method for gel dosimeter readout. because of hard accessibility and high cost of sample reading by mri systems, some other alternative methods were developed. the optical computed...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید