نتایج جستجو برای: magic f polymer gel dosimeters

تعداد نتایج: 505330  

Journal: :Physics in medicine and biology 2007
Stephen Bosi Pourandokht Naseri Alicia Puran Justin Davies Clive Baldock

There is a need for stable gel materials for phantoms used to validate optical computerized tomography (CT) scanners used in conjunction with radiation-induced polymerizing gel dosimeters. Phantoms based on addition of light-absorbing dyes to gelatine to simulate gel dosimeters have been employed. However, to more accurately simulate polymerizing gels one requires phantoms that employ light-sca...

2008
Yves De Deene

The use of polymer gels to record radiation dose distributions in three dimensions was first proposed in 1992 as a proof-of-principle [1]. The accuracy of these early polymer gel dosimeters and scanning methods was not sufficient for most clinical applications [2]. Since then, several efforts were made to increase the accuracy and precision of both the physical gel dosimeter and the scanning te...

Journal: :Physics in medicine and biology 2001
J V Trapp S A Bäck M Lepage G Michael C Baldock

Changes in the linear attenuation coefficient of polymer gel dosimeters post-irradiation enable the imaging of dose distributions by x-ray computed tomography (CT). Various compositions of polymer gel dosimeters manufactured from acrylamide (AA), and N,N'-methylene-bis-acrylamide (BIS) comonomers and gelatin or agarose gelling agents were investigated. This work shows that increasing the comono...

Journal: :Applied sciences 2022

Proton pencil beam scanning is a dynamic delivery technique with excellent conformability to the tumor volume. The accuracy of spot size and positions will have significant effect on delivered dose distribution. We employed polymer gel dosimeters measure for Shanghai Advanced Therapy facility (SAPT). Polymer (MAGAT-f PAGAT) were utilized full width at half maximum (FWHM) various depths basis th...

Journal: :iranian journal of radiation research 0
k. adinehvand borujerd islamic azad university, borujerd, iran m.h. zahmatkesh novin radiation medicine institute, tehran, iran m.r aghamiri division of radiation medicine, shahid beheshti university, tehran, iran sh. akhlaghpour department of radiology, tehran university of medical sciences, tehran, iran s. bagheri novin radiation medicine institute, tehran, iran

background: the purpose of this study was to evaluate the dependency of magica polymer gel dosimeter response (r2) on different electron energies as well as on different mean dose rate for a standard clinically used linear accelerator. materials and methods: the sensitivity of the dosimeter was represented by the slope of calibration curve in the linear region measured for each modality. a cali...

Journal: :Journal of Physics: Conference Series 2006

2011
K. Adinehvand B. Azadbakht

The purpose of this study was to evaluate dependence of MAGICA polymer gel dosimeter 1/T2 on different electron energies as well as on different mean dose rates for a standard clinically used Linear accelerator. A calibration curve (in the linear region) based on 12 dosimeters (11 irradiated and one background) was obtained for 6MeV electron beam. Dose rate of dependence was studied in 10MeV el...

Journal: :Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics 2008
B Hill A J Venning C Baldock

Polymer gel dosimetry undertaken on a multislice CT scanner provides an alternative method to conventional dosimetry measurements. Polymer gel dosimeters were used to measure CT radiation doses and compared to TLD and ionization chamber measurements in different diameter phantoms. CTDI was investigated for each of these phantoms for a range of mAs (100-400 mAs), tube voltage (100-135 kV) and no...

K. Adinehvand, M.H. Zahmatkesh, M.R Aghamiri, S. Bagheri, Sh. Akhlaghpour,

Background: The purpose of this study was to evaluate the dependency of MAGICA polymer gel dosimeter response (R2) on different electron energies as well as on different mean dose rate for a standard clinically used linear accelerator. Materials and Methods: The sensitivity of the dosimeter was represented by the slope of calibration curve in the linear region measured for each modalit...

Journal: :Journal of Physics: Conference Series 2006

نمودار تعداد نتایج جستجو در هر سال