نتایج جستجو برای: lower corrosion current density and higher coating corrosion resistance than the other composite formulations this nanocomposite provided superior protection against corrosion in sodium chloride solution

تعداد نتایج: 24316310  

In this research, ZnO nanoparticles modified with imidazole in O-xylene solution and characterized with Fourier transform infrared FTIR spectroscopy. Then, polyaniline-ZnO unmodified and imidazole modified nanocomposites were synthesized via in-situ emulsion polymerization method. The synthesized nanocomposites were characterized by FTIR and scanning electron microscopy SEM. The anti-corrosion ...

Composite and nanocomposite Ni-Co/SiC coatings were synthesized by electro-codeposition of micro and nano-sized SiC particles with average diameter of 10m and 20nm using horizontal electrodes. Surface morphology, chemical composition, phase composition, hardness and corrosion resistance of the deposited coatings were studied using SEM observations and EDX, XRD, microhardness and polarization ...

Journal: :iranian journal of hydrogen and fuel cell 0
ali hedayati department of engineering sciences and mathematics, luleå university of technologies saeed asghari institute of materials and energy, iranian space research center amir hosein alinoori institute of materials and energy, iranian space research center morteza koosha institute of materials and energy, iranian space research center esa vuorinen department of engineering sciences and mathematics, luleå university of technologies

in the polymer electrolyte membrane fuel cells (pemfcs), low corrosion resistance and high interfacial contact resistance (icr) are two controversial issues in usage of aisi 316l stainless steel as a metallic bipolar plate. for solving these problems, investigation and development of different coatings and/or surface treatments are inevitable. corrosion behavior and icr of aisi 316l specimens c...

Journal: :Science and technology of advanced materials 2008
Florica Simescu Hassane Idrissi

We outline the ability of zinc phosphate coatings, obtained by chemical conversion, to protect mild steel rebars against localized corrosion, generated by chloride ions in alkaline media. The corrosion resistance of coated steel, in comparison with uncoated rebars and coated and uncoated steel rebars embedded in mortar, were evaluated by open-circuit potential, potentiodynamic polarization, cro...

ژورنال: مجله دندانپزشکی 2002
فتحی, محمدحسین, موسوی, سیدبهروز, مرتضوی, وجیه السادات ,

Nowadays, application of implants as a new method for replacing extracted teeth have been improved. So, many researches have been performed for improving the characteristics of implants. The aim of this study was to design and produce a desired coating in order to obtaining two goals including improvement of the corrosion behavior of metallic endodontic implant and the bone osseointegration sim...

Journal: :journal of physical and theoretical chemistry 0
m. rezaei nasab department of chemistry, shahid bahonar university of kerman, kerman 76175, iran m. shahidi department of chemistry, kerman branch, islamic azad university, kerman, iran s.m.a. hosseini department of chemistry, shahid bahonar university of kerman, kerman 76175, iran

in this work, polypyrrole/ceo2 nanocomposite (nc) was synthesized in the presence of methylorange as a reactive self-degraded soft template. the field emission scanning electron microscopy(fesem) images indicate that the ceo2 nps have a nucleus effect and cause a homogenous ppycore–shell type morphology with an encapsulation of the ceo2 core by the ppy shell. the effect ofnc on acrylic waterbor...

پایان نامه :وزارت علوم، تحقیقات و فناوری - دانشگاه ارومیه 1377

the methods which are used to analyze microstrip antennas, are divited into three categories: empirical methods, semi-empirical methods and full-wave analysis. empirical and semi-empirical methods are generally based on some fundamental simplifying assumptions about quality of surface current distribution and substrate thickness. thses simplificatioms cause low accuracy in field evaluation. ful...

Journal: :journal of mechanical research and application 2012
s. abuali galedari m. mousavi khoei

plasma electrolytic oxidation (peo) is the new, environmentally and cost-effective method for coating the metals. this method vastly has been studied for coating aluminum, titanium and magnesium and their alloys and recently for steel. in present study, ck45 steel samples were coated by peo method in order to improve corrosion resistance. during this process specimens were immerged in carbonate...

Journal: :journal of dentistry, tehran university of medical sciences 0
mh. fathi v. mortazavi

statement of problem: many attempts have been made in order to evaluate the amalgam corrosion behavior as an indicator of biocompatibility. purpose: the aim of this study was to evaluate and compare the initial corrosion of four different brands of dental amalgams. materials and methods: four different types of commercial high copper dental amalgam were studied. a special mold was used and twen...

, ,

In this paper, zirconium oxide ceramics coating (ZrO2) were produced on Zircaloy-4 alloy using plasma electrolytic oxidation (PEO). Sodium silicate and Sodium aluminate based electrolyte was selected in PEO process and the effects of the concentration of Sodium aluminate (0, 2.5, 5, 7.5, and 10 g/L) on the microstructure, phase structure and the behavior of corrosion of formed coatings. In orde...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید