نتایج جستجو برای: knee prosthesis

تعداد نتایج: 93113  

Background: The ultimate goal of the treatment of infectious knee arthritis is to protect the articular cartilage fromadverse effects of infection. Treatment, however, is not always hundred percent successful and has a 12% failurerate. Persistent infection is more likely to happen in elderly patients and those with underlying joint diseases,particularly osteoarthritis. Eradica...

2014
Mohd Afzan Mohd Anuar Mitsugu Todo Ryuji Nagamine Shunji Hirokawa

The primary objective of this study is to distinguish between mobile bearing and fixed bearing posterior stabilized knee prostheses in the mechanics performance using the finite element simulation. Quantifying the relative mechanics attributes and survivorship between the mobile bearing and the fixed bearing prosthesis remains in investigation among researchers. In the present study, 3-dimensio...

2012
Hajime Yamanaka Ken-ichiro Goto Munetaka Suzuki

BACKGROUND Total knee arthroplasty (TKA) is a common form of treatment to relieve pain and improve function in cases of rheumatoid arthritis (RA). Good clinical outcomes have been reported with a variety of TKA prostheses. The cementless Hi-Tech Knee II cruciate-retaining (CR)-type prosthesis, which has 6 fins at the anterior of the femoral component, posterior cruciate ligament (PCL) retention...

2014
Girish N. Swamy Conal Quah Elmunzar Bagouri Nitin P. Badhe

This paper reports a case of fatigue fracture of the femoral component in a cruciate-retaining cemented total knee arthroplasty (TKA). A 64-year-old man had undergone a primary TKA for osteoarthritis 10 years previously at another institution using the PFC-Sigma prosthesis. The patient recovered fully and was back to his regular activities. He presented with a history of sudden onset pain and l...

Journal: :The Journal of arthroplasty 2013
M Mashfiqul A Siddiqui Ngai Nung Lo Shaifuzain Ab Rahman Pak Lin Chin Shi-Lu Chia Seng Jin Yeo

The aim of this study is to determine the success rate in eradication of early methicillin-resistant Staphylococcus aureus (MRSA) prosthetic joint infection. Rate of prosthesis retention and functional outcome between patients with prosthesis retention and prosthesis revision were compared. All patients who underwent primary total knee arthroplasty between May 1998 and September 2008 at our ins...

2015
Samuel F. Thompson Blake E. Peterson Ajay Aggarwal

A 62-year-old man underwent total knee arthroplasty using a mobile-bearing prosthesis. Four days post-operatively the patient experienced the first of several acute knee dislocations. Closed reduction was performed at an outside hospital a total of three times prior to presentation at this institution. A two-stage exchange of the TKA was recommended due to the clinical suspicion for an infected...

Journal: :Journal of orthopaedic surgery 2012
Harjoban Singh Vivek Mittal Biren Nadkarni Shekhar Agarwal Divesh Gulati

PURPOSE To compare outcomes in Indian women who underwent total knee arthroplasty (TKA) using the standard Legacy Posterior Stabilised (LPS) versus the gender-specific LPS high-flexion knee prosthesis. METHODS 100 women (200 knees) aged 60 to 80 years with an arc of flexion of ≥90º underwent simultaneous sequential TKA for primary osteoarthritis of both knees. They were randomised to receive ...

Journal: :Clinical Orthopaedics and Related Research 2009
Young-Hoo Kim Sung-Hwan Yoon Jun-Shik Kim

UNLABELLED Although the design features of the Medial Pivot fixed-bearing prosthesis reportedly improve kinematics compared with TKAs using fixed-bearings, clinical improvements have not been reported. We asked whether the clinical and radiographic outcomes, ranges of motion of the knee, patient satisfaction, and complication rates would be better in knees with a Medial Pivot fixed-bearing pros...

Journal: :Romanian journal of morphology and embryology = Revue roumaine de morphologie et embryologie 2017
Daniela TarniŢă Dan Marian Calafeteanu IonuŢ Daniel Geonea Alin Petcu DănuŢ Nicolae TarniŢă

In this paper, the complex 3D virtual model of the prosthetic knee is obtained using embedded applications: DesignModeler and SpaceClaim under ANSYS Workbench 14.5 software package. A number of six cases of prosthetic knee joint assembly, depending on the malalignment angle, are developed. Stress maps and the values of the maximum von Mises stress on the three prosthesis components: polyethylen...

Journal: :Acta orthopaedica Belgica 2013
Jaap Brunnekreef Gerjon Hannink Maarten de Waal Malefijt

The purpose of the study was to compare the recovery of knee mobility after two-stage revision of an infected total knee arthroplasty using a static or mobile spacer. At 12 months follow-up, none of the patients had a recurrent infection of their new prosthesis. Knee flexion was lower in the static spacer group at 3, 6 and 12 months postoperatively. Patients that received a mobile spacer had a ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید