نتایج جستجو برای: iodide ion selective electrode

تعداد نتایج: 461721  

Journal: :international journal of environmental research 2011
h. bagheri sadeghi h. sid kalal h. hoveidi z. molavi n. adeli asl

a new cesium ion selective pvc membrane based on parent calix [4] arene was developed for potentiometric determination of cesium in environmental samples. the electrode based on p-5,11,17,23tetra(tertbutyl) 25,26,27,28-tetrahydroxy calix[4]arene(thc) as ionophor ,dibutyl phthalate (dbp)as plasticizer ,sodium tetra phenyl borate(natpb)and oleic acid as lipophilic salt and additive showed the ...

Journal: :journal of physical & theoretical chemistry 2011
m.h. fekri m. darvishpour e. baghdar

a poly(vinyl chloride) membrane based on a new a-dioxime derivative as membrane carrier was prepared andinvestigated as a cr(iii) selective electrode. the electrode exhibits a good potentiometric response for cr(iii)over a wide concentration range 1.0 x 10-6 to 1.0 x 10-1 m with a slope 19.5+0.5 mv/decade and low detectionlimit of 8.9 x 10-7 m. it has a fast response time < 15 s. the best perfo...

Journal: :journal of physical & theoretical chemistry 2015
h. aghaie m. h. felcri m. arvand k. zare m. aghaie

a pvc membrane cr(iii) ion selective electrode has been constructed using 2h-1,4-benzothioazine-2,3(4h)dione dioxime (btd) as membrane carrier. the influence of membrane composition on the electroderesponse was studied. the electrode exhibits a nernstian response over a cr(iii) concentration range of 1.0 x10 6 to 1.0>< 10-1 m (r = 0.99) with a slope of 19.5 ± 0.5 mv per decade of concentration,...

Journal: :physical chemistry and electrochemistry 0

a pvc ion-selective membrane electrode based on cd-tetraphenyl porphyrine as a carrier was prepared fordetermination of mno4- ion. this electrode revealed good selectivity toward permanganate ion over a widevariety of anions. effects of some experimental parameters such as nature of the plasticizer, the amounts ofcarrier and additive, and concentration of the internal solution on the potential ...

Journal: :Analytical sciences : the international journal of the Japan Society for Analytical Chemistry 2002
Mohammad Reza Ganjali Tahereh Poursaberi Morteza Hosseini Masoud Salavati-Niasary Mohammad Yousefi Mojtaba Shamsipur

A highly selective PVC membrane electrode based on a cerium-salen complex was prepared. The sensor displays an anti-Hofmeister selectivity sequence with a preference for iodide ion over many common organic and inorganic anions. The proposed electrode exhibits a near-Nernstian behavior over a wide concentration range (5.0 x 10(-2) - 8.0 x 10(-6) M) with a slope of 57.5 mV per decade, and a detec...

Journal: :Analytical chemistry 2016
Lukasz Mendecki Xiaorui Chen Nicole Callan David F Thompson Benjamin Schazmann Sergio Granados-Focil Aleksandar Radu

Novel solid-contact iodide-selective electrodes based on covalently attached 1,2,3 triazole ionic liquid (IL) were prepared and investigated in this study. Triazole-based IL moieties were synthesized using click chemistry and were further copolymerized with lauryl methacrylate via a simple one-step free radical polymerization to produce a "self-plasticized" copolymer. The mechanical properties ...

Journal: :Analytical sciences : the international journal of the Japan Society for Analytical Chemistry 2003
Demet Kuruoğlu Esin Canel Shahabuddin Memon Mustafa Yilmaz Esma Kiliç

A hydrogen ion-selective poly(vinyl chloride) membrane electrode was constructed using 5,11,17,23-tetra-tert-butyl-25,26,27,28-tetracyanomethoxycalix[4]arene as a neutral carrier. The electrode showed an apparent Nernstian response in the 2-11.5 pH range with a slope of 54.0 +/- 0.2 mV/pH at 20 +/- degrees C. This electrode showed a rapid response of the emf to changes in the pH, high ion selec...

2011
A. A. Hathoot

Poly 8-(3-acetylimino-6-methyl-2,4-dioxopyran)-1-aminonaphthalene (PAMDAN) films were electrodeposited on platinum electrode (Pt), forming PAMDAN/Pt modified electrode, to study its utility in electrooxidation of iodide ion. The electrooxidation process was investigated by cyclic voltammetry. The effects of different factors e.g. scan rate, iodide ion concentration, film thickness and acid conc...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید