نتایج جستجو برای: immunosensor

تعداد نتایج: 1035  

2011
Rosana A. S. Fonseca Joilson Ramos-Jesus Lauro T. Kubota Rosa F. Dutra

A piezoelectric immunosensor based on gold nanoparticles (AuNPs) co-immobilized on a dithiol-modified surface is proposed for detection of human cardiac troponin T (TnT). Anti-human troponin T (anti-TnT) antibodies were covalently immobilized on the nanostructured electrode surface by thiol-aldehyde linkages. In a homogeneous bulk solution, TnT was captured by anti-TnT immobilized on the QCM el...

Journal: :Clinical chemistry 2009
Yong Huang Tai-Hong Wang Jian-Hui Jiang Guo-Li Shen Ru-Qin Yu

BACKGROUND Analysis of trace proteins plays an essential role in the fields of biomedical research and clinical diagnosis. Development of methods for the detection of proteins at very low concentrations has historically been a challenge in immunochemistry. We have developed an electrical immunosensor for the detection of prostate specific antigen (PSA). METHODS The electrical immunosensor use...

2013
Ying Zhu Yaoyao Cao Xia Sun Xiangyou Wang

In this paper, an amperometric immunosensor for the detection of carbofuran was developed. Firstly, multiwall carbon nanotubes (MWCNTs) and graphene sheets-ethyleneimine polymer-Au (GS-PEI-Au) nanocomposites were modified onto the surface of a glass carbon electrode (GCE) via self-assembly. The nanocomposites can increase the surface area of the GCE to capture a large amount of antibody, as wel...

Journal: :Scientific reports 2016
Reza Riahi Seyed Ali Mousavi Shaegh Masoumeh Ghaderi Yu Shrike Zhang Su Ryon Shin Julio Aleman Solange Massa Duckjin Kim Mehmet Remzi Dokmeci Ali Khademhosseini

There is an increasing interest in developing microfluidic bioreactors and organs-on-a-chip platforms combined with sensing capabilities for continual monitoring of cell-secreted biomarkers. Conventional approaches such as ELISA and mass spectroscopy cannot satisfy the needs of continual monitoring as they are labor-intensive and not easily integrable with low-volume bioreactors. This paper rep...

Journal: :The Analyst 2010
María Moreno-Guzmán Marcos Eguílaz Susana Campuzano Araceli González-Cortés Paloma Yáñez-Sedeño José M Pingarrón

A novel electrochemical immunosensor using screen-printed carbon electrodes and functionalized magnetic particles was developed for the determination of cortisol. Anti-cortisol antibody was immobilized onto protein A-modified magnetic particles and a direct competitive immunoassay involving cortisol antigen labeled with alkaline phosphatase (AP) was employed. The resulting conjugate was trapped...

Journal: :Analytical chemistry 2013
Qiaoling Yu Xuefang Zhan Kunping Liu Hao Lv Yixiang Duan

In this study, antibody immobilization using a microwave-induced H2O/Ar plasma pretreatment was achieved for the first time. Plasma was used to activate the surface of a capillary-based immunosensor by increasing the density of silicon hydroxyls and dangling bonds to ensure better silanization. The capture antibodies were covalently immobilized after the silanized surface reacted with glutarald...

2013
Niramol Punbusayakul Saikat Talapatra Pulickel M Ajayan Werasak Surareungchai

BACKGROUND A label-free immunosensor from as-grown double wall carbon nanotubes (DW) bundles was developed for detecting Salmonella typhimurium. The immunosensor was fabricated by using the as-grown DW bundles as an electrode material with an anti-Salmonella impregnated on the surface. The immunosensor was electrochemically characterized by cyclic voltammetry. The working potential (100, 200, 3...

2011
Xia Sun Shuyuan Du Xiangyou Wang Wenping Zhao Qingqing Li

In this study, an anti-carbofuran monoclonal antibody (Ab) was immobilized on the surface of a glassy carbon electrode (GCE) using silica sol-gel (SiSG) technology. Thus, a sensitive, label-free electrochemical immunosensor for the direct determination of carbofuran was developed. The electrochemical performance of immunoreaction of antigen with the anti-carbofuran monoclonal antibody was inves...

Journal: :Journal of chromatography. B, Analytical technologies in the biomedical and life sciences 2016
Shu Hwang Ang T Malathi Thevarajah Pei Meng Woi Yatimah Binti Alias Sook Mei Khor

An immunosensor that operates based on the principles of lateral flow was developed for direct detection of hemoglobin A1c (HbA1c) in whole blood. We utilized colloidal gold-functionalized antibodies to transduce the specific signal generated when sandwich immuno-complexes were formed on the strip in the presence of HbA1c. The number and intensity of the test lines on the strips indicate normal...

2011
Ning Gan Jianguo Hou Fu-Tao Hu Yuting Cao Tianhua Li Zhiyong Guo Jun Wang

An ultrasensitive and renewable electrochemiluminescence (ECL) immunosensor was developed for the detection of tumor markers by combining a newly designed trace tag and streptavidin-coated magnetic particles (SCMPs). The trace tag (RuL@SiO(2)-Au~RuL-Ab2) was prepared by loading Ru(bpy)(3)(2+)(RuL)-conjuged secondary antibodies (RuL-Ab2) on RuL@SiO(2) (RuL-doped SiO(2)) doped Au (RuL@SiO(2)-Au)....

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید