نتایج جستجو برای: hvmv substation

تعداد نتایج: 1955  

2017
T. E. Lee

Understanding domestic electricity consumption behaviour is very important for planners and operators of electrical networks. Distribution Network Operators (DNOs) are installing monitoring devices at the low-voltage (LV) substation level. However, monitoring devices need to be allocated with consideration. This paper seeks to quantify the relationship between key information from a substation ...

1967
STANLEY A. CHANGNON

Cooperative substation records of hail and thunder incidences have been used as a source of data to devclop more accurate and detailed average patterns of these phenomena. Since the accuracy and completeness of records by volunteer observers are generally considered questionable, a method of determining accurate substation records of thunder and hail was devised. The evaluation method relies st...

2003
Rahmat Shoureshi Tim Norick David Linder John Work Paula Kaptain

An essential step toward the development of an intelligent substation is to provide self-diagnosing capability at the equipment level. Transformers, circuit breakers and other substation equipment should be enabled to detect their potential failures and make life expectancy prediction without human interference. This paper focuses on the development of an on-line equipment diagnostics using art...

2012
Ikbal Ali

High-speed and reliable mechanism is required to support peer-to-peer communications for implementing distributed functions in Substation Automation System (SAS). This paper presents the practical implementation and testing of protection scheme based on high-speed peer-to-peer communication using GOOSE (Generic Object Oriented Substation Event) message model in a laboratory setup. An analysis o...

2003
M. A. Omidiora

Condition monitoring of power substations is a significant issue for the National Electric Power Authority (NEPA) of Nigeria. Current methods for monitoring the condition of high voltage equipment are time consuming and often inaccurate, therefore causing catastrophic damage to the substation equipment. Recent research has demonstrated the efficacy of employing optical fiber sensors in conditio...

2013
Ahmed Abdolkhalig Rastko Zivanovic

This paper presents performance evaluation of a new architecture for phasor estimation within IEC 61850 substation Process-Bus. To benefit from the raw IEC 61850-9-2 Sampled Measured Values streamed with high sampling rate from various Merging Units at substation bay level, Unsented Kalman Filter is proposed to be utilized in the computation of Phasor at substation process level to enhance the ...

2004
R SUBRAMANIAN H AL HOSANI

Developments in computer and communication technologies have enabled unmatched integration of a wide range of substation functions within a computer control system. This new class of application has gone through a great deal of effort into achieveing cost-effective, efficient, secure and high performance of the utility power grid substation operations. The integrated Substation Control System (...

2012
O. P. Rahi Abhas Kumar Singh Shashi Kant Gupta Shilpa Goyal

This paper presents the design of earthing system for 132 KV substation and simulation for calculation of required parameters. This paper is to provide information pertinent to safe earthing practices in ac substation design and to establish the safe limits of potential difference under normal and fault conditions. The grounding grid system of a practical 220 kV substation is calculated by MATL...

2013
Huan Huang Hualin Liu Hong Luo Hao Du Yi Xing Yexu Li Farid P. Dawalibi Haijun Zhou Longhai Fu

This paper examines various aspects of the design process and subsequent field test measurements of a large and complex substation grounding system. The study and measurements show that soil layering and lead interference can have a significant impact on the appropriate test location that yields the exact substation ground impedance. Applying a specific percentage rule such as the 61.8% rule fo...

2015
Stjepan Jonjić Zoran Baus Marinko Barukčić

Abstract – This paper investigates overvoltages on the SF6 substation enclosure caused by the switching operation of the interrupter. The paper analyzes the amplitude and the overvoltage duration on the substation enclosure. Switching overvoltages take part in the everyday drive of HV substations and constitute an undesired phenomenon that may often, beside transient disturbances, lead to undes...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید