نتایج جستجو برای: humeral stem loosening

تعداد نتایج: 286756  

2001

Introduction: Approximately 15 to 20 percent of all proximal humeral fractures are displaced and require operative treatment [1]. Reduced bone quality of the humeral head complicates internal fixation and may result in implant loosening, fracture re-displacement and poor functional outcome for the patient [2, 3]. Little is known about the effect of bone mineral density (BMD) on internal fixatio...

Journal: :Journal of orthopaedic trauma 2006
Paul C Siffri Richard D Peindl Edward R Coley James Norton Patrick M Connor James F Kellam

OBJECTIVE To compare the mechanical stability of a fixed-angle blade plate with that of a locking plate in a cadaveric proximal humerus fracture-fixation model subjected to cyclic loading. A secondary objective was to evaluate whether the use of synthetic humerus specimens would replicate significant differences found during cadaveric tests. DESIGN Mechanical evaluation of constructs in bendi...

2013
A. Panagopoulos P. Tsoumpos K. Evangelou Christos Georgiou I. Triantafillopoulos

Background. The purpose of this study was to report our experience with shoulder hemiarthroplasty in the context of old trauma. Methods. 33 patients with failed treatment for a complex proximal humeral fracture underwent prosthetic hemiarthroplasty. There were 15 men and 18 women with a mean age of 58.1 years. The average period from initial treatment was 14.9 months. Sequelae included 11 malun...

Background: The purpose of this study was to examine the mid-term functional outcomes, radiographic results,and revision rates of patients treated with the Delta Xtend Reverse Shoulder System for both primary and revisionarthroplasty indications.Methods: A retrospective review was conducted of records for all individuals who underwent a reverse shoulderarthroplasty using the Delta Xtend Reverse...

Journal: :The Journal of bone and joint surgery. British volume 1995
V V Raut P D Siney B M Wroblewski

We reviewed 351 cemented revisions of femoral stems performed for aseptic loosening. At a mean of six years after the revision operation 72.1% of the patients were pain-free and 21.4% had only mild or occasional discomfort. The latest radiographs showed definite stem loosening in 10 (2.8%) and 20 hips (5.7%) had required rerevision, only nine (2.6%) of which were for mechanical failure of the s...

2018
Philipp R. Heuberer Georg Brandl Leo Pauzenberger Brenda Laky Bernhard Kriegleder Werner Anderl

BACKGROUND Stemless shoulder arthroplasty is a fairly new concept. Clinical and radiological follow-up is essential to prove implant safety and concept. This prospective single-centre study was performed to evaluate the influence of radiological changes on clinical mid-term outcome following stemless humeral head replacement with hollow screw fixation. METHODS Short- and mid-term radiological...

Journal: :The Journal of bone and joint surgery. British volume 1996
M Watson

A bipolar spacer was inserted for severe arthritic destruction of the shoulder in 14 patients, and followed up for a mean of 5.9 years. In one patient the operation failed because of infection. Two others required revision for loss of low-friction properties which caused loosening of the humeral component. At the end of the follow-up all the patients showed improvement. The Hospital for Special...

2016
Martin Clauss Lilianna Bolliger Daniel Brandenberger Peter E Ochsner Thomas Ilchmann

BACKGROUND AND PURPOSE There are 2 basic principles in cemented stem fixation: shape-closed and force-closed. We investigated 2 shape-closed straight stems, the Müller (MSS) and the Virtec (VSS), which differ only in geometrical cross section, to determine whether the difference in stem shape would affect the radiological results or long-term survival. PATIENTS AND METHODS We included 711 hip...

Journal: :Journal of shoulder and elbow surgery 2012
Stephen B Gunther Tennyson L Lynch Desmond O'Farrell Christian Calyore Andrew Rodenhouse

HYPOTHESIS The success of shoulder arthroplasty surgery has been limited by a common complication: glenoid implant loosening. Eccentric loading of the glenoid due to migration of the humeral head is considered to be the major cause of glenoid loosening and is referred to as the rocking-horse phenomenon. Glenoid implant loosening may cause pain, limitation of function, and the need for complicat...

2016
Laurent Obert Christelle Peyron Etienne Boyer Gauthier Menu François Loisel Sébastien Aubry

INTRODUCTION The shoulder arthroplasty brings satisfaction to patients in terms of quality of life and indolence. However whether anatomic implant or reverse, it does not escape from the loosening of the glenoid component. Moreover, optimal implantation is required to ensure the functional outcome without shortening of the arm. The purpose of this study is obtain CT scan evaluation of the gleno...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید