نتایج جستجو برای: field scanner

تعداد نتایج: 803839  

Journal: :European journal of radiology 2005
Roberto T Blanco Risto Ojala Juho Kariniemi Jukka Perälä Jaakko Niinimäki Osmo Tervonen

Magnetic resonance imaging (MRI) is a cutting edge imaging modality in detecting diseases and pathologic tissue. The superior soft tissue contrast in MRI allows better definition of the pathology. MRI is increasingly used for guiding, monitoring and controlling percutaneous procedures and surgery. The rapid development of interventional techniques in radiology has led to integration of imaging ...

Journal: :iranian journal of nuclear medicine 2009
parham geramifar mohammad reza ay mojtaba shamsaie zafarghandi george loudos arman rahmim

combined pet/ct scanners now play a major role in medicine for in vivo imaging in oncology, cardiology, neurology, and psychiatry. as the performance of a scanner depends not only on the scintillating material but also on the scanner design, with regards to the advent of newer scanners, there is a need to optimize acquisition protocols as well as to compare scanner performances on an objective ...

2010
Heeteak Chung Bart Lynch Sanjiv Samant

To report a study of the use of GAFCHROMIC EBT radiochromic film (RCF) digitized with a commercially available flatbed document scanner for accurate and reliable all-purpose two-dimensional (2D) absolute dosimetry within a clinical environment. We used a simplified methodology that yields high-precision dosimetry measurements without significant postirradiation correction. The Epson Expression ...

Journal: :journal of biomedical physics and engineering 0
a ghadimi-moghadam pediatric infectious ward,yasuj university of medical sciences, yasuj,iran s m j mortazavi ionizing and non-ionizing radiation protection research center (inirprc), shiraz university of medical sciences, shiraz, iran a hosseini-moghadam student research committee,shiraz university of medical sciences, shiraz,iran m haghani ionizing and non-ionizing radiation protection research center (inirprc), shiraz university of medical sciences, shiraz, iran s taeb ionizing and non-ionizing radiation protection research center (inirprc), shiraz university of medical sciences, shiraz, iran m a hosseini

mri workers are occupationally exposed to static and time-varying gradient magnetic fields.  while the 24-hour time-averaged exposure to static magnetic fields is about a few mt, the maximum static field strength can be as high as 500 mt during patient set up. over the past several years, our lab has performed extensive experiments on the health effects of exposure of animal models and humans t...

2013
G. Bringout T. M. Buzug

Introduction Magnetic Particle Imaging (MPI) is a new imaging technology aimed at the imaging of a tracer in the human body. First published in 2005 [1], the number of scanner prototypes is growing and there is always more room for optimisation in each new scanner design. The imaging principle is based on the non-linear magnetisation of magnetic nanoparticles. Placed in a magnetic field they ca...

2004
G. Giovannetti R. Francesconi L. Landini V. Viti M. F. Santarelli V. Positano A. Benassi

The main goal of this research was to demonstrate the utility of using a quadrature birdcage coil in lowpass version for magnetic resonance imaging (MRI) in open scanner at very low static field. When used in horizontal bore MRI systems, the birdcage coil is able to produce circular polarized field using quadrature excitation, thus reaching SNR improvement of 2 as maximum value. The birdcage co...

Journal: :CoRR 2017
Erik Dam

Scanner drift is a well-known magnetic resonance imaging (MRI) artifact characterized by gradual signal degradation and scan intensity changes over time. In addition, hardware and software updates may imply abrupt changes in signal. The combined effects are particularly challenging for automatic image analysis methods used in longitudinal studies. The implication is increased measurement variat...

Journal: :journal of lasers in medical sciences 0
akram sadat jafari roodbandi school of public health, occupational health department, bam university of medical sciences, bam, iran hamid naderi bsc of computer enginnering, ferdoos payam noor university, ferdoos, iran naser hashenmi-nejad school of public health, occupational health department, school of public health, kerman university of medical sciences, kerman, iran alireza choobineh research center for health sciences, institute of health, shiraz university of medical sciences, shiraz, iran mohammad reza baneshi research center for modeling in health, institute for futures studies in health, kerman university of medical sciences, kerman, iran vafa feyzi msc of occupational health, dezful university of medical sciences, dezful, iran

introduction: three-dimensional (3d) scanners are widely used in medicine. one of the applications of 3d scanners is the acquisition of anthropometric dimensions for ergonomics and the creation of an anthropometry data bank. the aim of this study was to evaluate the precision and accuracy of a modified 3d scanner fabricated in this study. methods: in this work, a 3d scan of the human body was o...

2008
David Price

Introduction MRI acoustic noise represents a possible hazard to patients and volunteers undergoing scanning and to workers present in the scanner room during imaging. Vibrations in the gradient coils are generated by Lorentz forces, induced by the currents flowing through the gradient coils within the static magnetic field. The vibrations are transmitted to other parts of the scanner and finall...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید