نتایج جستجو برای: fault current limiter

تعداد نتایج: 855006  

Journal: :IEEJ Transactions on Power and Energy 1990

2015
N. DEVARAJAN

In this paper performance analysis of Doubly Fed Induction Generator under abnormal condition is analysed. In recent years, this series compensated transmission system will produce unwanted effect of sub synchronous resonance. Super Conducting Magnetic Energy Storage (SMES) provides an efficient damping for sub synchronous resonance that will enhance power system stability in addition to real a...

Journal: :Journal of the Korean Institute of Illuminating and Electrical Installation Engineers 2014

By increasing the penetration level of the inverter-based distributed generations (IBDGs) in power system, their fault ride through capability has become one of the essential issues of the new grid codes. This paper proposes a novel method to limit inverter fault currents which are used in DGs. To achieve FRT, interface-inverter operates as a controlled voltage source during normal operation as...

2012
Wook - Won Kim Sung - Yul Kim Jin - O Kim

The fault current levels through the electric devices have a significant impact on failure probability. New fault current results in exceeding the rated capacity of circuit breaker and switching equipments and changes operation characteristic of overcurrent relay. In order to solve these problems, SFCL (Superconducting Fault Current Limiter) has rising as one of new alternatives so as to improv...

1999
Rachid Cherkaoui Bertrand Dutoit

|Transient stability investigations consist of studying the rotor oscillations of generators (electro-mechanic oscillations, 0.1-2 Hz) after the occurrence of a fault of large amplitude, e.g. short circuit. The goal is to indicate if the generators are capable to stay synchronous after a fault has occurred. The fault duration is one of the most important factors to be determined. In fact, the s...

2014
Mohamed M. Aly Emad A. Mohamed

One of the worst types of fault that a power system should be designed to withstand is a short circuit. Within the various types of fault current limiters, the superconducting fault current limiter (SFCL) has an extremely fast current limitation. The rapid switching action and the self-sensing nature of the superconductor make SFCLs particularly attractive in fault protection. This very fast ti...

Journal: :Iet Generation Transmission & Distribution 2022

DC fault clearance is one of the critical issues for modular-multilevel-converter-based high voltage direct current (MMC-HVDC) systems. Employing a hybrid circuit breaker (H-DCCB) to isolate faulty line typical method achieve fast clearance. However, H-DCCB has interrupt and absorb energy up tens megawatts in several milliseconds. Through theoretical analysis interruption process using H-DCCB, ...

Journal: :IOP Conference Series: Earth and Environmental Science 2020

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید