نتایج جستجو برای: fan beam collimator
تعداد نتایج: 126659 فیلتر نتایج به سال:
Helical tomotherapy (HT) is a novel treatment approach that combines Intensity-Modulate Radiation Therapy (IMRT) delivery with in-built image guidance using megavoltage (MV) CT scanning. The technique utilises a 6 MV linear accelerator mounted on a CT type ring gantry. The beam is collimated to a fan beam, which is intensity modulated using a binary multileaf collimator (MLC). As the patient ad...
PURPOSE In this article, the authors propose a multibeam field emission x-ray (MBFEX) system along with a half-scan fan-beam reconstruction algorithm. METHODS The proposed system consists of a linear CNT-based MBFEX source array, a single large area detector that is divided into same number of segments as the number of x-ray beams, a multihole collimator that aligns each beam with a correspon...
In order to achieve a thermal neutron beam for neutron radiography applications, a new neutron collimator has been designed, installed and characterized at Tehran Research Reactor (TRR). TRR is a 5 MW, open pool and light water coolant reactor with seven beam tubes. Neutron collimator that is an important part of neutron radiography system was installed in the six inch E beam tube. Collimator d...
The importance of collimator R&D with test beam facilities is demonstrated with the example of ILC collimator studies at SLAC End Station A. Related LHC collimator aspects and longer term plans are addressed. Presented at IDTB07, ILC Detector Test Beam workshop, Fermilab, USA, 2007.
A collimator is often used to clean a beam of its excessive tail particles. If the beam intensity is high enough or if the beam is brought too close to the collimator, however, the wakefields generated by the beam-collimator interaction can cause additional beam tails to grow, thus defeating, or even worsening, the beam-tail cleaning process. The wakefield generated by a sheet beam moving past ...
A specially designed high resolution converging collimator having a focal length of 50 cm has been evaluated for cone beam single photon emission computed tomography (SPECT). The focal region was investigated by imaging a point source placed at the expected focal point and along the central ray of the collimator in front of and behind the focal point. Technetium-99m point source sensitivities m...
For transmission computed tomography (TCT) systems using a centered transmission source with a fan-beam collimator, the transmission projection data are truncated. To achieve sufficiently large imaging field of view (FOV), we have designed the combination of an asymmetric fan-beam (AsF) collimator and a small uncollimated sheet-source for TCT, and implemented AsF sampling on a two-head SPECT sy...
The high beam intensities in the next linear collider can damage the collimation system jaws if a failure of the electronic machine protection system allows the acceleration of a mis-launched pulse. We are developing a prototype collimator that will allow a new jaw surface to be moved into place after beam damage. We are also developing a prototype collimator based on continuously reforming the...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید