Journal: :The International journal of oral & maxillofacial implants 2012
Marta Baldassarri Jenni Hjerppe Davide Romeo Stefan Fickl Van P Thompson Christian F J Stappert

PURPOSE Microgaps at the implant-abutment interface allow for microbial colonization, which can lead to peri-implant tissue inflammation. This study sought to determine the marginal accuracy of three different implant-zirconium oxide (zirconia) abutment configurations and one implant?titanium abutment configuration. MATERIALS AND METHODS Three combinations of implants with custom-made zirconi...

Journal: :The International journal of oral & maxillofacial implants 2017
Reza Saeidi Pour Peter Randelzhofer Daniel Edelhoff Otto Prandtner Caroline Freitas Rafael Anja Liebermann

The goal of this study was to explore an innovative approach to single-tooth replacement using an individually custom-fabricated, root-analog, hybrid dental implant, in the esthetic zone, to avoid the microgap and micromovements between the implant and abutment. Moreover, the use of burs to prepare the implant recipient site is not necessary in this technique, reducing the bone removal, heating...

2017
Piero Papi Stefano Di Carlo Francesca Mencio Daniele Rosella Francesca De Angelis Giorgio Pompa

OBJECTIVES Risk factors in oral implantology are defined as local or systemic conditions that increase failure rates. The purpose of this paper is to evaluate the long-term survival rate of dental implants placed in patients presenting mechanical risk factors. MATERIALS AND METHODS This retrospective study was conducted only with patients presenting at least one of the following risk factors ...

Journal: :Journal of periodontology 2007
Hideyuki Kawashima Shuichi Sato Mamoru Kishida Hiroaki Yagi Kazuma Matsumoto Koichi Ito

BACKGROUND Dental implants require regular maintenance. It is crucial that the instrument used for maintenance be able to remove plaque and calculus from the implant surface effectively and efficiently, while causing minimal damage to its circumference. Some ultrasonic scalers may be useful for implant maintenance; however, no clinical study has examined this. This study evaluated the treatment...

Journal: :Bio-medical materials and engineering 2014
Dandan Xia Hong Lin Shenpo Yuan Wei Bai Gang Zheng

Implant-abutment assemblies are usually subject to long-term cyclic loading. To evaluate the dynamic fatigue performance of implant-abutment assemblies with different tightening torque values, thirty implant-abutment assemblies (Zimmer Dental, Carlsbad, CA, USA) were randomly assigned to three tightening groups (24 Ncm; 30 Ncm; 36 Ncm), each consisted of 10 implants. Five specimens from each gr...

2013
T. Rack S. Zabler A. Rack H. Riesemeier K. Nelson

The implant-abutment connection of a two-piece dental implant depicts a complex micro-mechanical behavior: a micro-gap is evident at the implant-abutment interface, even in the virgin state. Its width varies when external mechanical load is applied. High resolution synchrotron-based radiography in combination with hard X-ray phase contrast to image this gap and estimate its size is deployed. Th...

2008
Gilbert Chahine Mari Koike Toru Okabe Pauline Smith Radovan Kovacevic

The production of customized Ti-6Al-4V ELI dental implants by electron beam melting technology makes it possible to mass produce customized dental implants which introduce a porous surface to promote better osseointegration. By fabricating the root-form implant and the abutment as one piece, the authors expect to eliminate fracturing at the abutment screw and prosthetic screw. This paper descri...

Journal: :فصلنامه علمی پژوهشی مهندسی مکانیک جامدات واحد خمینی شهر 0
masih firouzbakht msc. department of mechanical engineering, islamic azad university, khomeinishahr branch/isfahan, iran hamed ajabi naeeni assistant professor, department of mechanical engineering, islamic azad university, khomeinishahr branch/isfahan, iran mostafa pirmoradian assistant professor, department of mechanical engineering, islamic azad university, khomeinishahr branch/isfahan, iran

longevity of osseointegrated implants are intensely influenced by biomechanical factors. control of these factors prevents mechanical complications, which include fracture of screws, components, or materials veneering the framework. in this study, the impact of length and threads pitch of dental implants on the stress distribution and maximum von mises stress in implant-abutment complex and jaw...

 longevity of osseointegrated implants are intensely influenced by biomechanical factors. Control of these factors prevents mechanical complications, which include fracture of screws, components, or materials veneering the framework. In this study, the impact of length and threads pitch of dental implants on the stress distribution and maximum Von Mises stress in implant-abutment complex and ja...

Journal: :journal of dentistry, tehran university of medical sciences 0
mahasti sahabi assistant professor, department of prosthodontics, school of dentistry, shahid beheshti university of medical sciences, tehran, iran ; dental research center, research institute of dental sciences of shahid beheshti, university of medical sciences, tehran, iran. mehdi adibrad periodontist, department of periodontology, school of dentistry, isfahan university of medical science, isfahan, iran. fatemeh sadat mirhashemi dental research center, research institute of dental sciences of shahid beheshti, university of medical sciences, tehran, iran ; msc, ph.d student, mechanics of agricultural engineering, ferdowsi university of mashhad, mashhad, iran. sareh habibzadeh assistant professor, department of prosthodontist, tehran university of medical sciences, international campus, dental school, tehran, iran.

the purpose of this study was to determine the influence of platform switching on stress distribution of two different implant systems using three-dimensional (3d) finite element models.six 3d finite element models were created to replicate two different implant systems with peri-implant bone tissue, in which six different implant-abutment configurations were represented: model xive-a: 3.8-mm-d...