نتایج جستجو برای: czt detector

تعداد نتایج: 58904  

2004
A. E. Bolotnikov G. S. Camarda G. A. Carini G. W. Wright D. S. McGregor W. McNeil R. B. James

New data regarding performance studies of Frisch-grid CdZnTe (CZT) detectors are presented. The Frisch-grid detector configuration under investigation is a bar shaped CZT crystal with the side surfaces coated with an insulating layer. A Frisch grid is fashioned by inserting the CZT bar into a metallic sleeve, or by depositing the metal directly upon the insulator; hence the semiconductor materi...

2004
H. Krawczynski M. Groza

Cadmium Zinc Telluride (CZT) detectors are having a major impact on the field of hard X-ray astronomy. Without the need for cryogenic cooling they achieve good spatial and energy resolutions over the broad energy range from 10 keV to ∼600 keV. In this paper, we briefly review the historical development of detectors used in Xray astronomy. Subsequently, we present an evaluation of CZT detectors ...

Journal: :IEEE transactions on nuclear science 2005
L J Meng Z He

This paper presents a study for exploring the limiting timing resolution that can be achieved with a large volume 3-D position sensitive CZT detector. The interaction timing information was obtained by fitting the measured cathode waveforms to pre-defined waveform models. We compared the results from using several different waveform models. Timing resolutions, of ~9.5 ns for 511 keV full-energy...

Journal: :asia oceania journal of nuclear medicine and biology 0
yasuyuki takahashi department of nuclear medicine technology, gunma prefectural college of health sciences, maebashi, japan masao miyagawa department of radiology, ehime university graduate school of medicine, toon, japan yoshiko nishiyama department of radiology, ehime university graduate school of medicine, toon, japan naoto kawaguchi department of radiology, ehime university graduate school of medicine, toon, japan hayato ishimura department of radiological technology, ehime university hospital, toon, japan teruhito mochizuki department of radiology, ehime university graduate school of medicine, toon, japan

objective(s): the energy resolution of a cadmium-zinc-telluride (czt) solid-state semiconductor detector is about 5%, and is superior to the resolution of the conventional anger type detector which is 10%. also, the window width of the high-energy part and of the low-energy part of a photo peak window can be changed separately. in this study, we used a semiconductor detector and examined the ef...

2001
P. F. Bloser T. Narita J. A. Jenkins J. E. Grindlay

We present results from the flight of two prototype CZT detectors on a scientific balloon payload in September 2000. The first detector, referred to as “CZT1,” consisted of a 10 mm × 10 mm × 2 mm CZT crystal with a single gold planar electrode readout. This detector was shielded by a combination of a passive collimator in the front, giving a 40 degree field of view and surrounded by plastic sci...

2005
I. Jung M. Groza J. Perkins H. Krawczynski A. Burger

Cadmium Zinc Telluride (CZT) achieves excellent spatial resolution and good energy resolution over the broad energy range from several keV into the MeV energy range. In this paper we present the results of a systematic study of the performance of CZT detectors manufacturered by Orbotech (before IMARAD) depending on surface preparation, contact materials and contact deposition. The standard Orbo...

2007
A. E. Bolotnikov N. M. Abdul-Jabbar S. Babalola G. S. Camarda Y. Cui A. Hossain E. Jackson H. Jackson J. R. James A. L. Luryi R. B. James Larry A. Franks

In the past, various virtual Frisch-grid designs have been proposed for cadmium zinc telluride (CZT) and other compound semiconductor detectors. These include three-terminal, semi-spherical, CAPture, Frisch-ring, capacitive Frisch-grid and pixel devices (along with their modifications). Among them, the Frisch-grid design employing a noncontacting ring extended over the entire side surfaces of p...

Journal: :Physics in medicine and biology 2011
Y Gu J L Matteson R T Skelton A C Deal E A Stephan F Duttweiler T M Gasaway C S Levin

This paper investigates the performance of 1 mm resolution cadmium zinc telluride (CZT) detectors for positron emission tomography (PET) capable of positioning the 3D coordinates of individual 511 keV photon interactions. The detectors comprise 40 mm × 40 mm × 5 mm monolithic CZT crystals that employ a novel cross-strip readout with interspersed steering electrodes to obtain high spatial and en...

2012
Xiaowang Zhou Donald K. Ward Bryan M. Wong F. Patrick Doty Jonathan A. Zimmerman

Cd(1-x)Zn(x)Te (CZT) crystals are the leading semiconductors for radiation detection, but their application is limited by the high cost of detector-grade materials. High crystal costs primarily result from property nonuniformity that causes low manufacturing yield. Although tremendous efforts have been made in the past to reduce Te inclusions/precipitates in CZT, this has not resulted in an ant...

2001
J. M. Pérez Y. F. Du

This paper presents a simulation of the spectroscopic performance of two large CZT coplanar detectors, 1.5 1.5 cm area and 1.0 cm thick, with coplanar anodes. A code, based on the GEANT libraries and classical Monte Carlo sampling, was developed to simulate experimental scenarios. This code adapts the GEANT capabilities for simulating complex detection systems for spectroscopic studies. Detecto...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید