نتایج جستجو برای: coronary sinus flow

تعداد نتایج: 695494  

Journal: :Cardiovascular research 1997
M Zehetgruber G Porenta G Mundigler D Mörtl T Binder G Christ P Probst H Baumgartner G Maurer P Siostrzonek

OBJECTIVE The present study was performed to compare coronary flow reserve by transesophageal Doppler echocardiography and intracoronary Doppler flow wire measurements in patients with LAD disease. METHODS 17 patients with various degree of LAD stenosis were studied. Intracoronary LAD Doppler measurements were performed at baseline and after intracoronary injection of 18 micrograms adenosine....

Journal: :Circulation 1971
W Ganz K Tamura H S Marcus R Donoso S Yoshida H J Swan

In 14 subjects with normal coronary arteries the mean coronary sinus blood flow was 122 25 mI/min (range, 83 to 159 ml/min). The blood flow computed per 100 g of left ventricle was 82 + 16 ml/min, which is in the range of values obtained by nitrous oxide and coincidence counting methods. In 35 patients with arteriographically confirmed coronary artery disease the mean flow was similar (128 + 20...

Journal: :European Journal of Cardio-Thoracic Surgery 2004

Journal: :Circulation 1975
M Bassan W Ganz H S Marcus H J Swan

The changes in coronary blood flow in response to intracoronary injection of 3 ml of 76% Renografin were studied in 47 patients using the thermodilution technique for continuous measurement of coronary sinus blood flow. Within seconds after left coronary injection, an increase in coronary sinus flow began which peaked at an average of 53% above control in 5-10 seconds. There was a corresponding...

2005
DONALD R. RICCI ARTHUR E. ORLICK PAUL W. DOHERTY PAUL R. CIPRIANO DONALD C. HARRISON

A 50-year-old man suffering from recurrent chest pain accompanied by transient ST-segment elevation developed spasm of the left anterior descending coronary artery after receiving ergonovine maleate. During spontaneous chest pain, thermodilution coronary sinus blood flow fell from 96 ml/min to 46 ml/min, while the coronary sinus arteriovenous oxygen difference widened from 9.82 volumes percent ...

Journal: :British heart journal 1988
T Crake R Canepa-Anson L Shapiro P A Poole-Wilson

Coronary sinus oxygen saturation was measured continuously during incremental atrial pacing in 34 patients undergoing cardiac catheterisation. In eleven patients with normal coronary arteriograms, negative exercise tests, and no ST segment depression on the electrocardiogram, an increase in the rate of atrial pacing transiently decreased coronary sinus oxygen saturation but within 20 s oxygen s...

2015
Xiao Zhi Zheng Bin Yang Jing Wu

BACKGROUND For diagnosis of significant coronary artery stenosis, the most accurate parameter among the conventional echocardiographic parameters remains unknown. OBJECTIVES To assess the diagnostic efficacy of conventional echocardiographic parameters in the diagnosis of significant coronary artery stenosis and their correlation with the percentage of stenosis considering conventional corona...

Journal: :the journal of tehran university heart center 0
saeed davoodi national iranian oil company central hospital, tehran, iran. yaddollah dadashi national iranian oil company central hospital, tehran, iran. manouchehr madani civi national iranian oil company central hospital, tehran, iran. seyed hesameddin abbasi national iranian oil company central hospital, tehran, iran. amir hossien sami national iranian oil company central hospital, tehran, iran. kyomars majdi national iranian oil company central hospital, tehran, iran.

in this paper, we describe a case of an aneurysmal circumflex artery connected to the coronary sinus through a fistula in a 40-year-old man with a two-year history of palpitation and chest pain. we discussed surgical management for patients with coronary artery fistula (caf), particularly for asymptomatic patients with a small left-to-right shunt .

Journal: :Circulation 1978
D G Mathey K Chatterjee J V Tyberg J Lekven B Brundage W W Parmley

In seven patients thermodilution coronary sinus flow (TD-CSF) was higher (164 +/- 21 ml/min) during ventricular pacing than during atrial pacing (119 +/- 21 ml/min, P less than 0.005) at identical heart rate, without an increase in the determinants of myocardial oxygen consumption. To assess the possibility of right atrial admixture in coronary sinus blood during ventricular pacing we compared ...

Journal: :the journal of tehran university heart center 0
mohammad hasan namazi cardiovascular research center/shaheed beheshti university of medical sciences, tehran, iran. morteza safi cardiovascular research center/shaheed beheshti university of medical sciences, tehran, iran. hassan kamalzadeh cardiovascular research center/shaheed beheshti university of medical sciences, tehran, iran. reza karbasi cardiovascular research center/shaheed beheshti university of medical sciences, tehran, iran.

a 55-year-old man referred for cardiac resynchronization therapy (crt) due to severe heart failure. a severe stenosis in the coronary sinus vein after the posterior branch disallowed the insertion of the lead. nevertheless, the stenosis was dilated and the left ventricle (lv) lead was implanted in the lateral marginal branch.

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید