نتایج جستجو برای: confined concrete

تعداد نتایج: 115914  

2015
Mostafa Osman

Since columns are the most important elements of the structures, failure of one column in a critical location can cause a progressive collapse. In this respect, the repair and strengthening of columns is a very important subject to reduce the building failure and to keep the columns capacity. Twenty columns with different parameters is tested and analysis. Eleven typical confined reinforced con...

2008
Franco Braga Rosario Gigliotti Michelangelo Laterza Michele D’Amato

Abstract: In order to evaluate the capacity of RC members, the main codes allow the use of stress-strain laws that can reproduce closely the real behaviour of concrete, as opposed to parabola-rectangular or equivalent rectangular diagrams. Both sectional strength and ductility depend on the law of concrete, therefore they are influenced by the confinement of members, as evidenced in the literat...

Journal: :Concrete Research and Technology 1991

Journal: :Ain Shams Engineering Journal 2011

2017
Iman Mansouri Ozgur Kisi Pedram Sadeghian Chang-Hwan Lee Jong Wan Hu

This paper investigates the effectiveness of four different soft computing methods, namely radial basis neural network (RBNN), adaptive neuro fuzzy inference system (ANFIS) with subtractive clustering (ANFIS-SC), ANFIS with fuzzy c-means clustering (ANFIS-FCM) and M5 model tree (M5Tree), for predicting the ultimate strength and strain of concrete cylinders confined with fiber-reinforced polymer...

2009
YeongAe Heo Sashi K. Kunnath

Accurate constitutive models of the constituent materials in a reinforced concrete (RC) section, namely, unconfined concrete, confined concrete and reinforcing steel are necessary in fiber-based discretization of RC components for use in nonlinear analysis of RC structures. This paper examines the sensitivity to different constitutive models in predicting the inelastic seismic behavior of RC fr...

2014
Yiyan Lu Shan Li

This paper presents the results of an experimental study into the behavior of concrete-filled steel tube columns confined by fiber-reinforced polymer (FRP). Eleven columns were tested to investigate the effects of the FRP layer number, the thickness of the steel tube and concrete strength on their load capacity and axial deformation capacity. The experimental results indicated that the FRP wrap...

Ali Kheiroddin Ali Reza Morteza'ee

Flanged shear walls are used extensively in moderate- and high-rise buildings to resist lateral loads induced by earthquakes. The seismic performance of many buildings is, therefore, closely linked to the behavior of the reinforced concrete walls. They must be carefully designed to provide not only adequate strength, but also sufficient ductility to avoid brittle failure under strong lateral lo...

2016
G. Campione L. Cavaleri

The improvement and the capacity assessment of existing buildings has become the main topic of the last years so that different studies can be found devoted to damaged structures or structures not having a capacity compatible with the safety levels of the actual codes. Reinforced concrete framed structure buildings represent a conspicuous rate of the existing constructions so many efforts are a...