نتایج جستجو برای: cerrobend block

تعداد نتایج: 158718  

Journal: :Journal of Applied Clinical Medical Physics 2016

Journal: :journal of biomedical physics and engineering 0
f seif arak university of medical sciences m j tahmasebi-birgani ahvaz jundishapur university of medical sciences m r bayatiani arak university of medical sciences

background: in this study, a method for linear attenuation coefficient calculation was introduced. methods: linear attenuation coefficient was calculated with a new method that base on the physics of interaction of photon with matter, mathematical calculation and x-ray spectrum consideration. the calculation was done for cerrobend as a common radiotherapy modifier and mercury. results: the valu...

Background: In this study, a method for linear attenuation coefficient calculation was introduced.Methods: Linear attenuation coefficient was calculated with a new method that base on the physics of interaction of photon with matter, mathematical calculation and x-ray spectrum consideration. The calculation was done for Cerrobend as a common radiotherapy modifier and Mercury.Results: The values...

ژورنال: سنجش و ایمنی پرتو 2015

The usage of digital radiology systems with insufficient quality control of digital image detectors can efface inherent superiorities of digital systems in comparison with analogue radiology systems and even makes an increased level of patients’ radiation doses. Modulation transfer function (MTF) is one of the most important parameters related to image quality and digital detectors efficiency. ...

Introduction: The head scatter factor (Sc) is important to measurements radiation beam and beam modeling of treatment planning systems used for advanced radiation therapy techniques. This study aimed to investigate the design of a mini-phantom to measurement variations in collimator Sc in the presence of shielding blocks for shaping the beam using different field sizes. <str...

پایان نامه :وزارت علوم، تحقیقات و فناوری - پژوهشگاه پلیمر و پتروشیمی ایران - پژوهشکده پتروشیمی 1389

this is an original study on the effect of a polyisobutylene – polydimethylsiloxane (pibpdms) block copolymer modifier used as an interfacial active agent on the dynamics behaviour of single newtonian drops suspended in a polyisobutylene (pib) newtonian matrix. the results were divided in two sections. the first part included the experiments carried out on the non-modified and 2% block cop...

2012
Mustafa Kamal

Mustafa Kamal, Abu-Bakr El-BediwiTamer Dawod* and Adel. S. Waqlan** Metal Physics Lab. Physics Department, Faculty of Science –Mansoura University, Egypt. * Medical Physics Unit, Clinical Oncology and Nuclear Medicine Dept., Faculty of Medicine, Mansoura University **On leave, M.sc student, Ministry of Higher Education, Yemen. [email protected], [email protected] [email protected]...

پایان نامه :وزارت علوم، تحقیقات و فناوری - دانشگاه فردوسی مشهد 1389

تخمین ساختار ثانویه پروتئین یکی از مهمترین مسائل در بیوانفورماتیک است. این تخمین معمولاً با روش های آزمایشگاهی انجام می گیرد که به دلیل هزینه بر و زمان بر بودن آن، یافتن راه حلی ارزانتر با زمان محاسبه معقول مورد توجه محققین قرار گرفته است. روش های رایانه ای گوناگون مانند شبکه های عصبی مصنوعی و مدل مارکف مخفی (hmm) ، راه حل های پیشنهادی برای تخمین ساختار ثانویه پروتئین هستند. اگرچه با استفاده از ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید