نتایج جستجو برای: cardiac output estimation

تعداد نتایج: 698528  

2017
Prescilla Perrichon Martin Grosell Warren W. Burggren

Understanding cardiac function in developing larval fishes is crucial for assessing their physiological condition and overall health. Cardiac output measurements in transparent fish larvae and other vertebrates have long been made by analyzing videos of the beating heart, and modeling this structure using a conventional simple prolate spheroid shape model. However, the larval fish heart changes...

2005
JOHN S. COLOCOUSIS LEE L. HUNTSMAN P. WILLIAM CURRERI

The purpose of this study was to conduct a controlled evaluation of the continuous-wave Doppler technique for the estimation of stroke volume changes. Six anesthetized dogs were studied. Aortic blood velocity was recorded from the suprasternal notch by a special continuous-wave Doppler unit. Cardiac output was varied by fluid infusion and exsanguination, and over 300 simultaneous records of aor...

Journal: :Archives of disease in childhood 2003
S M Tibby I A Murdoch

Systolic cardiac function results from the interaction of four interdependent factors: heart rate, preload, contractility, and afterload. Heart rate can be quantified easily at the bedside, while preload estimation has traditionally relied on invasive pressure measurements, both central venous and pulmonary artery wedge. These have significant clinical limitations; however, adult literature has...

2013
Ladislav Soukup Vlastimil Vondra Ivo Viščor Pavel Jurák Josef Halámek

The methods and device for estimation of cardiac output and measurement of pulse wave velocity simultaneously is presented here. The beat-to-beat cardiac output as well as pulse wave velocity measurement is based on application of electrical impedance method on the thorax and calf. The results are demonstrated in a study of 24 subjects. The dependence of pulse wave velocity and cardiac output o...

Journal: :British journal of anaesthesia 1993
R R Kennedy A B Baker

Measurements of the rate of uptake of soluble gases such as nitrous oxide or acetylene has been used as the basis of a method of cardiac output estimation since 1912. Using theoretical models of single, multiple and rebreathing techniques of cardiac output measurement, we determined the effect of solubility in blood and lung tissue on the changes in the final expired concentration of the gas. D...

Journal: :Critical care and resuscitation : journal of the Australasian Academy of Critical Care Medicine 2004
T Ong M A Gillies R Bellomo

Continuous cardiac output measurement using pulse contour analysis is a technique gaining widespread acceptance in intensive care units. We report a case where a pulse contour analysis computer (PiCCO, Pulsion Medical Systems, Munich, Germany) failed to calibrate in a patient who was undergoing induced hypothermia for anoxic brain injury. Despite several attempts to calibrate, using increased c...

Journal: :American journal of physiology. Regulatory, integrative and comparative physiology 2011
Manabu Shibasaki Thad E Wilson Morten Bundgaard-Nielsen Thomas Seifert Niels H Secher Craig G Crandall

An estimation of cardiac output can be obtained from arterial pressure waveforms using the Modelflow method. However, whether the assumptions associated with Modelflow calculations are accurate during whole body heating is unknown. This project tested the hypothesis that cardiac output obtained via Modelflow accurately tracks thermodilution-derived cardiac outputs during whole body heat stress....

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید