نتایج جستجو برای: cardiac catheterization pulmonary veins septal occluder device
تعداد نتایج: 1169863 فیلتر نتایج به سال:
BACKGROUND In this study, we sought to analyze our experience in urgent surgical management for embolized cardiac septal and ductal occluder devices resulting from trans-catheter closure of atrial septal defect, ventricular septal defect and patent ductus arteriosus in childhood patient group. METHODS We retrospectively reviewed 9 patients (aged 2-15 years) who underwent urgent surgery due to...
OBJECTIVES This study assessed the ability of live/real time three-dimensional transesophageal echocardiography (3DTEE) in measuring (1) atrial septal defect (ASD) maximum dimension, area, and adjacent rim size, (2) ASD occluder left and right atrial disk size, (3) length of contact between the left atrial (LA) disk and the aorta, and in (4) assessing device related complications such as residu...
Percutaneous device closure of atrial septal defect (ASD) is an alternative treatment to surgery. The main advantages of the percutaneous approach include avoidance of surgery, short procedure time and hospital length, in addition to comparable rates of complications. However, percutaneous device closure is associated with infrequent early and late complications including device embolization, a...
BACKGROUND Transcatheter closure of ostium secundum atrial septum defect (ASDII) using the new self-centering occluder, Amplatzer Septal Occluder (ASO), has been well developed in recent years. We describe the importance and role of transesophageal echocardiography (TEE) in the selection and closure of such defects. METHODS Thirty patients referred for transcatheter closure of ASDII by ASO we...
The usefulness of two-dimensional and Doppler echocardiography during buttoned double-disk device closure of an atrial septal defect was evaluated in 20 consecutive patients at the time of interventional catheterization. Transesophageal echocardiography was used in 11 patients (ages 5 to 62 years, weights 20 to 91 kg). Because of the size of the available transesophageal echo probe, transthor...
BACKGROUND The right-to-left shunt at the atrial level is responsible for arterial hypoxemia in patients with atrial septal defect. OBJECTIVES This study investigated the mechanism of arterial hypoxemia in patients with atrial septal defect by measuring the P(O2) in both the right and left upper pulmonary veins. SUBJECTS AND METHOD We prospectively measured the P(O2) in the femoral artery a...
Transcatheter device closure was performed under general anesthesia in all the patients. The interventional treatment modality was approved by the ethics committee of our hospital, and informed consent was obtained before the procedure. Femoral artery and vein was routinely punctured. Left ventricular angiography was performed at 60° left anterior oblique and 20° cranial tilt position. The entr...
AIMS There existed an ambiguity in the current echo literature about the identification of the pulmonary veins imaged by echocardiography. This study was designed to identify the site and blood flow of individual pulmonary veins by transthoracic echocardiography. METHODS AND RESULTS Transthoracic echocardiography was used to display individual pulmonary veins in the apical and parasternal sho...
BACKGROUND The purpose of this study was to outline the midterm follow-up results and complications in patients who underwent transthoracic device closure of an atrial septal defect (ASD) with the very large domestic occluder (44-48 mm). METHODS The data of 35 patients who underwent transthoracic device closure of an ASD with the very large domestic occluder (44-48 mm) at our institution were...
An alternative to the surgical repair of secundum type atrial septal defects (ASD) and of patent ductus arteriosus (PDA) is transcatheter closure. However, there is limited information about the efficacy of using percutaneous devices to close multiple ASDs. An 8-year-old female patient was admitted to our hospital with a cardiac murmur. A large secundum multi-fenestrated ASD (17 mm, 4.5 mm, 3 m...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید