نتایج جستجو برای: brachytherapy gamma sources

تعداد نتایج: 415361  

Objective: Brachytherapy sources are widely used for the treatment of cancer. The report of Task Group No. 43 (TG-43) of American Association of Physicists in Medicine is known as the most common method for the determination of dosimetric parameters for brachytherapy sources. The aim of this study is to obtain TG-43 dosimetric parameters for 60Co, 137Cs, 192Ir and 103Pd brachyt...

D. Shahbazi-Gahrouei, M. Hosseinpour, M.B. Tavakoli,

Background: For an effective treatment planning in brachytherapy, it is necessary to know the accurate source dosimetric information such as air kerma strength, exposure rate constant, dose rate constant and redial dose distribution. The usual method to determine these factors is thermo luminescent dosimeter (TLD) dosimetry. Nowadays, another more accurate method is known to be the Monte Carlo ...

2017
Prabhakar Ramachandran

Traditional brachytherapy refers to the placement of radioactive sources on or inside the cancer tissues. Based on the type of sources, brachytherapy can be classified as radionuclide and electronic brachytherapy. Electronic brachytherapy uses miniaturized X-ray sources instead of radionuclides to deliver high doses of radiation. The advantages of electronic brachytherapy include low dose to or...

Journal: :iranian journal of medical physics 0
fatemeh lotfalizadeh department of ray-medical engineering, shiraz university, shiraz, iran mehrnoosh karimipourfard department of ray-medical engineering, shiraz university, shiraz, iran bentolhoda amanat department of physics, payame noor university, tehran, iran mehdi zehtabian department of ray-medical engineering, shiraz university, shiraz, iran

introduction based on task group no. 43 (tg-43u1) recommendations, water phantom is proposed as a reference phantom for the dosimetry of brachytherapy sources. the experimental determination of tg-43 parameters is usually performed in water-equivalent solid phantoms. the purpose of this study was to determine the conversion factors for equalizing solid phantoms to water. materials and methods t...

Journal: :Medical physics 2006
Ali S Meigooni Shahid B Awan Kai Dou

Recently, elongated brachytherapy sources (active length >1 cm) have become commercially available for interstitial prostate implants. These sources were introduced to improve the quality of brachytherapy procedures by eliminating the migration and seed bunching associated with loose seed-type implants. However, the inability to calibrate elongated brachytherapy sources with the Wide-Angle Free...

2016
Haeyoung Kim Joo Young Kim Juree Kim Won Park Young Seok Kim Hak Jae Kim Yong Bae Kim

OBJECTIVE The aim of the present study was to acquire information on brachytherapy resources in Korea through a national survey of radiation oncologists. METHODS Between October 2014 and January 2015, a questionnaire on the current status of brachytherapy was distributed to all 86 radiation oncology departments in Korea. The questionnaire was divided into sections querying general information...

Ali. S. Meigooni Bentolhoda Amanat, Fatemeh Lotfalizadeh, Mehdi Zehtabian, Mehrnoosh Karimipourfard, Neda Zaker Sedigheh Sina

Introduction Based on Task Group No. 43 (TG-43U1) recommendations, water phantom is proposed as a reference phantom for the dosimetry of brachytherapy sources. The experimental determination of TG-43 parameters is usually performed in water-equivalent solid phantoms. The purpose of this study was to determine the conversion factors for equalizing solid phantoms to water. Materials and Methods T...

ژورنال: سنجش و ایمنی پرتو 2019

Brachytherapy is one type of internal radiation therapy where radiation sources, which are usually encapsulated are placed as close as possible to the tumor site inside the patient's body. In this technique, it is important to determine dose distribution around the brachytherapy capsule. Hereby, in this paper, dosimetric parameters of I-125 brachytherapy source model 6711 are estimated accordin...

2011
Stefan Strohmaier Grzegorz Zwierzchowski

This paper compares the isotopes (60)Co and (192)Ir as radiation sources for high-dose-rate (HDR) afterloading brachytherapy. The smaller size of (192)Ir sources made it the preferred radionuclide for temporary brachytherapy treatments. Recently also (60)Co sources have been made available with identical geometrical dimensions. This paper compares the characteristics of both nuclides in differe...

ژورنال: سنجش و ایمنی پرتو 2017

Intravascular brachytherapy is simulated with Palmaz-Schatz stent, manufactured by Cordis Co. that is radioactived with 188Re source, using the MCNPX code. Functions and dosimetric parameters, were calculated in  cylindrical coordinates and results compared with the latest standards and AAPM TG-60 group offers, published experimental data and also other performed simulations with various p...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید