نتایج جستجو برای: boron neutron capture therapy bnct

تعداد نتایج: 829713  

Journal: :Radiation research 1999
P D Bradley A B Rosenfeld B Allen J Coderre J Capala

Reverse-biased silicon p-n junction arrays using Silicon-On-Insulator technology have been proposed as microdosimeters. The performance of such detectors in boron neutron capture therapy (BNCT) is discussed. This work provides the first reported measurements using boron-coated silicon diode arrays as microdosimeters in BNCT. Results are in good agreement with measurements with gas proportional ...

پایان نامه :وزارت علوم، تحقیقات و فناوری - دانشگاه صنعتی اصفهان - دانشکده فیزیک 1390

درمان توسط گیر اندازی نوترون به وسیله بور یا boron neutron capture therapy(bnct) یکی از روش‏های مورد توجه در درمان بعضی سرطان‏ها از جمله تومورهای مغزی به نام گلیوبلاستوما، است. در این روش درمان، ابتدا بور به صورت یک ترکیب خاص که به وسیله مواد تومور دوست نشان‏دار شده است درون تومور متمرکز می‏شود، سپس یک باریکه از نوترون‏های فوق حرارتی با انرژی و شدت مناسب بر روی منطقه تومور تابانده می‏شود. انرژی...

Journal: :Biomaterials 2021

Combination cancer therapy (e.g., radiochemotherapy) is widely used to enhance the therapeutic effects and prevent recurrence of cancer. However, side monotherapy are also amplified when treating with combination therapy. A locally activated drug delivery strategy that can release payload in a tumor-selective manner greatly needed overcome Here, we explore potential combining boron neutron capt...

F. Rahmani, H Khalafi, S.M. Abtahi, S.M.R. Aghamiri,

Background: The aim of this work was to establish how well gel dosimeters performed, as substitutes for brain tissue compared with standard phantom materials such as water, polymethyl-methacrylate (or PMMA), A150 plastic and TE- liquid phantom material for dosimetry of neutron beams in boron neutron capture therapy. Materials and Methods: Thermal neutron fluence, photon dose and epithermal neu...

Journal: :Anticancer research 2003
Yasushi Shibata Akira Matsumura Tetsuya Yamamoto Hiroyoshi Akutsu Susumu Yasuda Kei Nakai Tadao Nose Kazuyoshi Yamamoto Hiroaki Kumada Naohiko Hori Shinichi Ohtake

BACKGROUND In boron neutron capture therapy, blood boron concentration is the key factor to calculate radiation dose, however, blood sampling is difficult during neutron irradiation. MATERIALS AND METHODS The prediction of blood boron concentrations for BNCT treatment planning has been prospectively investigated using patient data obtained at first craniotomy after the infusion of a low dose ...

2015
Masayori Ishikawa Kenichi Tanaka Satrou Endo Masaharu Hoshi

Phantom experiments to evaluate thermal neutron flux distribution were performed using the Scintillator with Optical Fiber (SOF) detector, which was developed as a thermal neutron monitor during boron neutron capture therapy (BNCT) irradiation. Compared with the gold wire activation method and Monte Carlo N-particle (MCNP) calculations, it was confirmed that the SOF detector is capable of measu...

2005
A. Valda D. M. Minsky A. J. Kreiner A. A. Burlon H. Somacal

Within our activities on accelerator-based boron neutron capture therapy (BNCT) carried out at the Tandar Laboratory (Comisión Nacional de Energı́a Atómica, Argentina) we present here the study and design of a tomographic imaging system for the measurement of the spatial distribution of the absorbed dose during a BNCT session. The 10B(n,α)7Li boron neutron capture reaction produces a 478 keV gam...

Journal: :iranian journal of radiation research 0
x. tang department of nuclear science and engineering, nanjing university of aeronautics and astronautics, nanjing 210016, china x. tang department of nuclear science and engineering, nanjing university of aeronautics and astronautics, nanjing 210016, china d. shu department of nuclear science and engineering, nanjing university of aeronautics and astronautics, nanjing 210016, china c. geng department of nuclear science and engineering, nanjing university of aeronautics and astronautics, nanjing 210016, china c. gong department of nuclear science and engineering, nanjing university of aeronautics and astronautics, nanjing 210016, china s. hang department of nuclear science and engineering, nanjing university of aeronautics and astronautics, nanjing 210016, china

background: boron neutron capture therapy (bnct) is a radiotherapy that combines biological targeting and high linear energy transfer. a potential therapeutic approach for non-small cell lung cancer (nsclc) is considered. however, dose in lung tumor is not homogeneous, and it will reduce the effect of bnct treatment. in order to improve the dose distribution of bnct, the multi-field irradiation...

C. Geng, C. Gong, D. Chen, D. Shu, H. Yu, S. Hang, X. Tang,

Background: Boron neutron capture therapy (BNCT) is a radiotherapy that combines biological targeting and high linear energy transfer. A potential therapeutic approach for non-small cell lung cancer (NSCLC) is considered. However, dose in lung tumor is not homogeneous, and it will reduce the effect of BNCT treatment. In order to improve the dose distribution of BNCT, the multi-field irradiation...

2017
Charles A Maitz Aslam A Khan Peter J Kueffer John D Brockman Jonathan Dixson Satish S Jalisatgi David W Nigg Thomas A Everett M Frederick Hawthorne

Boron neutron capture therapy (BNCT) was performed at the University of Missouri Research Reactor in mice bearing CT26 colon carcinoma flank tumors and the results were compared with previously performed studies with mice bearing EMT6 breast cancer flank tumors. Mice were implanted with CT26 tumors subcutaneously in the caudal flank and were given two separate tail vein injections of unilamella...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید