نتایج جستجو برای: biochemical oxygen demand

تعداد نتایج: 477091  

Rapid development and population growth have resulted in an ever-increasing level of water pollution in Malaysia. Therefore, this study was conducted to assess water quality of Selangor River in Malaysia. The data collected under the river water quality monitoring program by the Department of environment from 2005 to 2015 were used for statistical analyses. The local water quality indices were ...

2013
Sunita Verma Divya Tiwari Ajay Verma

Water samples were collected from river Pandu at six stations where human and animal activities were high. Composite samples were analyzed for dissolved oxygen (DO), biochemical oxygen demand (BOD), chemical oxygen demand (COD) , pH values during dry and wet seasons as well as the harmattan period. The total data points were used to establish relationships between the parameters and data were a...

Journal: :Environmental toxicology and chemistry 2008
Paul M Bradley Larry B Barber Dana W Kolpin Peter B McMahon Francis H Chapelle

The potential for in situ biodegradation of 4-nonylphenol (4-NP) was investigated in three hydrologically distinct streams impacted by wastewater treatment plants (WWTPs) in the United States. Microcosms were prepared with sediments from each site and amended with [U-ring-(14)C]4-n-nonylphenol (4-n-NP) as a model test substrate. Microcosms prepared with sediment collected upstream of the WWTP o...

2005
Bruce E. Logan

Insufficient oxygen transfer can result in anaerobic biofilms and odor generation during biochemical oxygen demand (BOD) removal in trickling filters, and can limit ammonia oxidation in nitrifying trickling filters. Since oxygen transfer to biofilms in plastic media trickling filters occurs by diffusion of oxygen through thin fluid films, previous models used solutions based on penetration theo...

2016
Yong Jiang Peng Liang Panpan Liu Yanhong Bian Bo Miao Xueliang Sun Helan Zhang Xia Huang

In the monitoring of pollutants in an aquatic environment, it is important to preserve water quality safety. Among the available analysis methods, the microbial fuel cell (MFC) sensor has recently been used as a sustainable and on-line electrochemical microbial biosensor for biochemical oxygen demand (BOD) and toxicity, respectively. However, the effect of the background organic matter concentr...

Journal: :Hua xi yi ke da xue xue bao = Journal of West China University of Medical Sciences = Huaxi yike daxue xuebao 1987
Z H Zhu M L Sun Z S Li Z C Yang T B Zhang Z C Heng B L Xiao Q Y Li Q Y Peng Y H Dong

The authors investigated different sulfolane concentrations in surface water and also performed the field study. The results showed that the practical threshold value of sulfolane affecting the organoleptic property (order) of water amounted to 10.6 mg/L. The sulfolane concentration did not inhibit the process of biochemical oxygen demand (BOD). The chronic threshold and no-effect doses for sul...

2017
Yingrong Wen Gerrit Schoups Nick van de Giesen

Organic pollution of rivers by wastewater discharge from human activities negatively impacts people and ecosystems. Without treatment, pollution control relies on a combination of natural degradation and dilution by natural runoff to reduce downstream effects. We quantify here for the first time the global sanitation crisis through its impact on organic river pollution from the threats of (1) i...

2016
Jianfeng Liu Xiang Zhang Jun Xia Shaofei Wu Dunxian She Lei Zou

Assessing the spatio-temporal variations of surface water quality is important for water environment management. In this study, surface water samples are collected from 2008 to 2015 at 17 stations in the Ying River basin in China. The two pollutants i.e. chemical oxygen demand (COD) and ammonia nitrogen (NH3-N) are analyzed to characterize the river water quality. Cluster analysis and the seaso...

Journal: :Anais da Academia Brasileira de Ciencias 2010
Jurandir Pereira-Filho Leonardo R Rörig Carlos A F Schettini Mariana A Soppa Bruno L Santana José Eduardo dos Santos

This study was carried out with the aim of evaluating the spatial variation of the water quality in the Itajaí-Açú River estuary. Seven stations along the estuary were monitored on a weekly basis, from October 2003 to December 2004, plus two stations in tributaries (Itajaí-Mirim River, the main tributary, and one reference station). This monitoring included measurements of salinity, pH, dissolv...

Journal: :Health laboratory science 1966
F W Gilcreas

The dilution biochemical oxygen demand (BOD) test has widespread application for design and operation of wastewater treatment processes, evaluating the quality of natural waters, and assessing the effect of wastewater discharges on these waters. While standardization of the BOD-measuring method has become of prime importance in maintaining dependable data acquisition, changes are made as needed...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید