نتایج جستجو برای: and shield
تعداد نتایج: 16828870 فیلتر نتایج به سال:
background it is remain a main concern that pediatric chest radiographies contribute to the significant radiation exposure to the thyroid gland as a more susceptible organ to radiation induced cancer. the aim of this study was to evaluate the entrance surface dose (esd) of pediatric chest radiography compared to the diagnostic reference levels (drl) and evaluation the efficacy of the lead (pb)...
The exposure buildup factors are important for determining the shield thickness of gamma and X-ray. Without taking this factor into account, the estimated thickness of the shield is less than what is expected which leads to an excessive received radiation exposure of staffs or patients. Given that the exposure buildup factor for the monoenergetic homogenous point sources have been calculated by...
composites with micro- and nano-metal fillers has attracted the attention of researchers for radiation shielding applications. Lead toxicity and heaviness have oriented extensive research toward the use of non-lead composite shields. The present study aimed to systematically review the efficiency of the composite shields of various micro- and nano-sized materials as composite shields have been ...
Crosstalk in VLSI interconnects is a major constrain in DSM and UDSM technology. Among various strategies followed for its minimization, shield insertion between Aggressor and Victim is one of the prominent options. This paper analyzes the extent of crosstalk in inductively coupled interconnects and minimizes the same through distributed shield insertion. Comparison is drawn between signal volt...
Radiofrequency (RF) shields have been recently developed for the purpose of shielding portions of the patient's body during magnetic resonance imaging (MRI) examinations. We present an experimental evaluation of a commercially available RF shield in the MRI environment. All tests were performed on 1.5 T and 3.0 T clinical MRI scanners. The tests were repeated with and without the RF shield pres...
background: in radiation therapy, peripheral dose or the dose outside the radiotherapy field, is important when anatomical structures with very low dose tolerances are involved. one of these critical organs in pelvic irradiation is testis. the amount of radiation delivered to the testes in radiotherapy must be kept as small as possible, consistent with the limit dose of this organ. the threshol...
introduction the use of cut-outs in electron applicators make changes on output, isodose, and percentage depth dose (pdd) curves. these changes and electron beam dose distribution in the form of three-dimensional (3d) can be measured by gel dosimeters. materials and methods dosimetry was performed with and without a square shield (6×6 cm2 field). the energies were 4, 9, and 16 mev and phantom w...
Introduction My previous note focused on pin 1 problems as an open door for RF into audio equipment. But RF can also enter equipment on the signal conductor(s) if the equipment fails to block it with an effective low pass filter. RF is induced on a shielded balanced pair by at least three mechanisms: • Imbalance in the magnetic coupling between the shield and the two signal conductors (Shield-c...
Metallic eye shields have been widely used for near-eye treatments to protect critical regions, but have never been incorporated into treatment plans because of the unwanted appearance of the metal artifacts on CT images. The purpose of this work was to test the use of an acrylic dummy eye shield as a substitute for a metallic eye shield during CT scans. An acrylic dummy shield of the same size...
Introduction: Due to the effect of radiation on both the tumor and the surrounding normal tissues, the side effects of radiation in normal tissues are expected. One of the important complications in the head and neck radiotherapy is the doses reached to the larynx and spinal cord of patients with non-laryngeal head and neck tumors. Materials and Methods: ...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید