نتایج جستجو برای: activating agents and monte carlo code

تعداد نتایج: 16886189  

  Monte Carlo simulation with CORSIKA code using QGSJET hadronic interaction model is applied on more than 5000 cosmic ray primaries to investigate dependence of maximum air shower development (Hmax) on mass and energy of primaries.

ژورنال: سنجش و ایمنی پرتو 2018

Monte Carlo method is the most accurate method for simulation of radiation therapy equipment. The linear accelerators (linac) are currently the most widely used machines in radiation therapy centers. Monte Carlo modeling of the Siemens Primus linear accelerator in 6 MeV beams was used. Square field size of 10 × 10 cm2 produced by the jaws was compared with TLD. Head simulation of Siemens accele...

Journal: :journal of medical signals and sensors 0
daryoush shahbazi-gahrouei saba ayat

introduction: radioiodine therapy is an effective method for treating thyroid cancer carcinoma, but it has some affects on normal tissues, hence dosimetry of vital organs are important to weigh the risks and benefits of this method. the aim of this study is to measure the absorbed doses of important organs by mcnp (monte carlo n particle) simulation and comparing the results of different method...

ژورنال: سنجش و ایمنی پرتو 2017

Brachytherapy is a therapeutic approach in which radioactive sources are used to irradiate malignant tumors from near distance. In this study, the comparison of dose distribution in iodine-125 source, STM 1251 and Oncoseed 6711 models was performed using the Monte Carlo Geant4 code. The results obtained from the Monte Carlo calculations have been compared with the TG43U1 formulation and also wi...

Journal: :journal of medical signals and sensors 0

an important need in radiation therapy is a fast and accurate treatment planning system. this system using ct data and characteristics of the radiation beam, calculates the dose in all points of the patient’s volume. two main factors in planning system are “accuracy” and “speed”. according to these factors, various generation of treatment planning systems are developed.   this article is the re...

Journal: :iranian journal of medical physics 0
mohammad taghi bahreyni toossi professor, medical physics research center, bu-ali research institute, mashhad university of medical sciences, mashhad, iran mehdi momen nezhad ph.d., linear accelerator dept., imam reza hospital, mashhad university of medical sciences, mashhad, iran seyed mohammad hashemi m.sc., medical physics research center, mashhad university of medical sciences, mashhad, iran

introduction: in recent decades, several monte carlo codes have been introduced for research and medical applications. these methods provide both accurate and detailed calculation of particle transport from linear accelerators. the main drawback of monte carlo techniques is the extremely long computing time that is required in order to obtain a dose distribution with good statistical accuracy. ...

A.A. Mowlavi, M. Yazdani,

Background: Monte Carlo determination of TG-43 brachytherapy dosimetry parameters and dose distribution calculation for 131Cs source model CS-1 are presented in this study. Materials and Methods: The dose distribution was calculated around the 131Cs Model CS-1 located in the center of 30 cm ×30 cm ×30 cm water, and soft tissue phantoms cube using MCNP code by Monte Carlo method. The percentage ...

ژورنال: کومش 2019
Jadidi , Majid , Rajabi , Hossein , Tajik-mansoury , Mohammad Ali, Taleshi Ahangari , Hadi ,

Introduction: Now day Ionizing radiation has found increasing applications in cancer treatment. However, in the treatment different kinds and size of tumors especially metastatic and small size tumors, conventional methods of external radiation therapy are not common. In radionuclide therapy, the use of monoclonal antibodies has made it possible to achieve maximum dose to small size tumor and m...

Abdolazim Sedighi Alireza Khoshghadam Mohammad Hadi Gholami, Mohammad Mohammadi,

Introduction: Because of importance of impact of the Source to Surface Distance (SSD) in determining of monitor unit for electron-therapy, it is essential to know the Virtual Source Position (VSP) for electron beam for a linear therapeutic accelerator for each energy and field size. , especially using the Khan method (photo distance squared method) And compare the results with...

ژورنال: سنجش و ایمنی پرتو 2020

Todays gamma knife radiosurgery is used widely for treatment of very small brain tumors. In order to investigate accuracy of dosimetry and treatment planning calculations, using Monte Carlo simulation with dedicated code named as beamnrc including non-CT data and CT data options is necessary. The aim of this study is choosing the best options in order to have an accurate tools based on their ad...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید