نتایج جستجو برای: 3d gel dosimetry

تعداد نتایج: 299187  

2015
Csaba Pinter Andras Lasso An Wang Gregory C. Sharp Kevin Alexander David Jaffray Gabor Fichtinger

Radiation therapy (RT) is a common treatment option for a wide variety of cancer types. Despite significant improvements in this technique over the past years, software tools for research in RT are limited to either expensive, closed, proprietary applications or heterogeneous sets of open-source software packages with limited scope, reliability, and user support. Our SlicerRT toolkit aspires to...

A. Takavar, A. Vaezzadeh, H.A. Nedaie, M. Keshtkar, M. Naderi, M.H. Zahmatkesh,

Background: Some tissues in human body are radiobiologically different from water and these inhomogeneity must be considered in dose calculation in order to achieve an accurate dose delivery. Dose verification in complex radiation therapy techniques, such as intensity‐modulated radiation therapy (IMRT) calls for volumetric, tissue equivalent and energy independent dosimeter. The purpose of this...

Journal: :iranian journal of radiation research 0
t. allahverdi pourfallah department of medical physics and biomedical engineering, tehran university of medical sciences, tehran, iran m. allahverdi department of medical physics and biomedical engineering, tehran university of medical sciences, tehran, iran n. riyahi alam department of medical physics and biomedical engineering, tehran university of medical sciences, tehran, iran m.r. ay research center for science and technology in medicine, tehran university of medical sciences, tehran, iran m.h. zahmatkesh novin medical radiation institute, tehran, iran

background: polymer gel dosimetry is still the only dosimetry method for direct measuring of threedimensional dose distributions. mri polymer gel dosimeters are tissue equivalent and can act as a phantom material. in this study the obtained isodose maps with pagat polymer gel dosimeter were compared to those calculated with egsnrs for singleshot irradiations of 8 and 18 mm collimators of gamma ...

M. Allahverdi, M.H. Zahmatkesh, M.R. Ay, N. Riyahi Alam, T. Allahverdi Pourfallah,

Background: Polymer gel dosimetry is still the only dosimetry method for direct measuring of threedimensional dose distributions. MRI Polymer gel dosimeters are tissue equivalent and can act as a phantom material. In this study the obtained isodose maps with PAGAT polymer gel dosimeter were compared to those calculated with EGSnrs for singleshot irradiations of 8 and 18 mm collimators of...

Journal: :iranian journal of medical physics 0
mohammad taghi bahreyni toossi professor, medical physics research center, faculty of medicine, mashhad university of medical sciences, mashhad, iran ghorban safaeian m.sc., in medical physics, mashhad university of medical sciences, mashhad, iran mohammad hosein bahreyni toossi professor, medical physics research center, faculty of medicine, mashhad university of medical sciences, mashhad, iran shahram baiani m.sc., in medical engineering, medical physics research center, faculty of medicine, mashhad university of medical sciences, mashhad, iran

introduction: the purpose of this work was to study the ability of mri normoxic polymer gel dosimetry for evaluating the dose distribution in hdr brachytherapy of esophagial cancer at imam reza brachytherapy center (mashhad, iran). materials and methods: initially, 2liters of normoxic gel (magic) was fabricated and then poured into 12 calibration test tubes and placed in a perspex walled phanto...

2016
Kurtis Dekker Jerry Battista Kevin Jordan

Introduction: Optical CT scanning of radiochromic gel dosimeters is a method for true 3D dosimetry, which is becoming increasingly needed as radiation therapy techniques become more advanced. Optical CT has developed from slow pencil beam laser scanners to fast cone-beam scanners using cameras. However, scattered light perturbs these broad-beam scanners, resulting in cupping artifacts and loss ...

2017
C Baldock

John Gore’s seminal 1984 paper on gel dosimetry spawned a vibrant research field ranging from fundamental science through to clinical applications. A preliminary bibliometric study was undertaken of the gel dosimetry family of publications inspired by, and resulting from, Gore’s original 1984 paper to determine active growth areas, research trends and hot topics from Gore’s paper up to and incl...

Journal: :Journal of Physics: Conference Series 2010

2001
Maria F. Chan Albert YC Fung Yu‐Chi Hu Chen‐Shou Chui Howard Amols Marco Zaider David Abramson

The BANG (MGS Research Inc., Guilford, CT) polymer gel has been used as a dosimeter to determine the three-dimensional (3D) dose distribution of a ruthenium-106 (Ru-106) ophthalmologic applicator. An eye phantom made of the BANG gel was irradiated with the Ru-106 source for up to 1 h. The phantom and a set of calibration vials were scanned simultaneously in a GE 1.5 T MR imager using the Hahn s...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید