نتایج جستجو برای: 3 d conformal radiotherapy

تعداد نتایج: 2281537  

Journal: :Acta otorhinolaryngologica Italica : organo ufficiale della Societa italiana di otorinolaringologia e chirurgia cervico-facciale 2004
V Donato N Bulzonetti A Monaco D Messineo R Caiazzo E Banelli

Head and neck tumours have poor prognosis: with surgery and radiotherapy, local control is achieved but is associated with damage to speech and swallowing function. Conventional 2-D radiotherapy is based on one fraction of 1.8-2.0 Gy per day; increasing the number of fractions, a higher dose can be administered, with an increase in local control. Today, conventional treatment can be replaced by...

Journal: :iranian journal of radiation research 0
s.a. vaezzadeh department of medical physics and biomedical engineering, tehran university of medical sciences, tehran, iran m. allahverdi department of medical physics and biomedical engineering, tehran university of medical sciences, tehran, iran h.a. nedaie department of radiotherapy – oncology, tehran university of medical sciences, tehran, iran m. aghili department of radiotherapy – oncology, tehran university of medical sciences, tehran, iran m. esfehani department of radiotherapy – oncology, tehran university of medical sciences, tehran, iran

background: to evaluate the dosimetric difference between conventional and three-dimensional conformal radiotherapy (3d-crt) using 6 and 18 mv x-ray photons. materials and methods: computed tomography scans of 26 pelvic patients were acquired and transferred to the 3d treatment planning system. for each patient, 8 conventional plans (3, 4, 5 and 6 fields) and one 3d-crt plan were prepared using...

Journal: :The Canadian journal of urology 2012
George Rodrigues

RODRIGUES G. Is intensity-modulated radiotherapy for prostate cancer ready for prime-time? Can J Urol 2012;19(4):6381-6382. the therapeutic ratio between the positive anticancer effect of radiotherapy on macroscopic and microscopic disease and the negative normal tissue effects leading to both acute and late radiotherapy toxicities. In the context of prostate cancer radiotherapy, these technolo...

Journal: :Scripta Medica 2005

Journal: :Oncology 2012
M Poudenx P Y Bondiau E Chamorey N Venissac J Otto N Pourel O Castelnau E Tessier B De Surmont Salasc J F Berdah D Pop C Michel J Mouroux

Concurrent chemoradiotherapy (CHRT) is the standard of care for unresectable locally advanced stage III non-small cell lung cancer. However, the optimal combination remains unclear. The aim of this study was to evaluate the efficacy of 2 induction chemotherapy cycles (days 1 and 22) with docetaxel 75 mg/m(2) and cisplatin 75 mg/m(2) followed by concurrent chemotherapy (weekly docetaxel-cisplati...

2016
Kyong Joo Lee Hong In Yoon Moon Jae Chung Jeong Youp Park Seungmin Bang Seung-woo Park Jin Sil Seong Si Young Song

BACKGROUND/AIMS Concurrent chemoradiotherapy (CCRT) is considered the treatment option for locally advanced pancreatic cancer, but accompanying gastrointestinal toxicities are the most common complication. With the introduction of three-dimensional conformal radiotherapy (3-D CRT) and intensity-modulated radiotherapy (IMRT), CCRT-related adverse events are expected to diminish. Here, we evaluat...

2013
Xiao-hui Ge Qiang Lin Xiao-cang Ren Yue-e Liu Xue-ji Chen Dong-ying Wang Yong-qiang Wang Bin Cao Zhi-gang Li Miao-ling Liu

BACKGROUND Patients with brain metastases from lung cancer have poor prognoses and short survival time, and they are often excluded from clinical trials. Whole-cranial irradiation is considered to be the standard treatment, but its efficacy is not satisfactory. The purpose of this phase II clinical trial was to evaluate the preliminary efficacy and safety of the treatment of whole-brain irradia...

Journal: :Medical physics 2008
Amit Sawant Raghu Venkat Vikram Srivastava David Carlson Sergey Povzner Herb Cattell Paul Keall

Tumor tracking using a dynamic multileaf collimator (DMLC) represents a promising approach for intrafraction motion management in thoracic and abdominal cancer radiotherapy. In this work, we develop, empirically demonstrate, and characterize a novel 3D tracking algorithm for real-time, conformal, intensity modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT)-based radiation...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید