نتایج جستجو برای: transthoracic contrast echocardiography
تعداد نتایج: 434997 فیلتر نتایج به سال:
Background Atrial septal defects (ASDs) are the most common third congenital heart defects. This study aimed to evaluate the clinical course of ASDs and the relationship between its complications, location closure and size. Materials and Methods: This cross-sectional study was conducted...
Patent foramen ovale (PFO) is implicated in platypnea-orthodeoxia, stroke and decompression sickness (DCS) in divers and astronauts. However, PFO size in relation to clinical illness is largely unknown since few studies evaluate PFO, either functionally or anatomically. The autopsy incidence of PFO is approximately 27% and 6% for a large defect (0.6 cm to 1.0 cm). A PFO is often associated with...
OBJECTIVE Large flap valve patent foramens may cause paradoxical thromboembolism and neurological decompression illness in divers. The ability of a self expanding Nitinol wire mesh device (Amplatzer septal occluder) to produce complete closure of the patent foramen ovale was assessed. PATIENTS Seven adults, aged 18-60 years, who had experienced neurological decompression illness related to di...
The early recognition and treatment of hydatid disease of the heart is important as it can result in potentially lethal complications. We present the clinical and echocardiographic features of a 71 year old Afghanistani man who presented with left-sided chest pain. Transthoracic (TTE), transesophageal (TEE), and contrast echo demonstrated a calcified cystic structure within the distal anterior ...
Background Transthoracic Doppler-echocardiography (TTE) is the standard clinical method for diagnosis and staging of aortic stenosis (AS). AS staging is based on measurement of aortic peak velocity, transvalvular gradient, and calculation of aortic valve area. Unidirectional throughplane phase-contrast magnetic resonance imaging (1DPC-MRI) has been widely applied in clinical imaging to quantify...
lthough transthoracic echocardiography is a well-established method of diagnosing vegetations in patients with infective endocarditis, its sensitivity for detection is relatively low and is operator-dependent. 1,2 We present a case of infective endocarditis in a patient with ventricular septal defect (VSD), diagnosed by cardiac magnetic resonance imaging (MRI). A 17-year-old man previously know...
Purpose: The aim of the present study was to evaluate the diagnostic accuracy for quantification of left ventricular (LV) volumes and LV ejection fraction (LVEF) with current echocardiographic methods of planimetry for analysis of LV remodeling after myocardial infarction in daily clinical routine. Methods: 26 patients were investigated directly after interventional therapy at hospital pre-disc...
UNLABELLED A papillary fibroelastoma is a rare, avascular, cardiac tumour that is often found incidentally using transthoracic echocardiography (TTE). Peripheral i.v. injection of a microbubble contrast agent is often used to characterize abnormal masses within the heart allowing further delineation of physical features, the area of attachment, and vascularity of the mass in order to differenti...
We present a case of posterior ventricular septal rupture associated to left ventricular aneurysm manged, during peri-operative period, by transthoracic and transesophageal echocardiography. Three-dimensional transesophageal echocardiography findings add adjunctive and more accurate information regarding morphological details of the ventricular septal rupture rather than two-dimensional echocar...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید