نتایج جستجو برای: tonometry

تعداد نتایج: 2118  

Journal: :Journal of biomechanics 2015
M A Lago M J Rupérez F Martínez-Martínez C Monserrat E Larra J L Güell C Peris-Martínez

This work presents a methodology for the in vivo characterization of the complete biomechanical behavior of the human cornea of each patient. Specifically, the elastic constants of a hyperelastic, second-order Ogden model were estimated for 24 corneas corresponding to 12 patients. The finite element method was applied to simulate the deformation of human corneas due to non-contact tonometry, an...

2015
Du Ri Seo Seung Joo Ha

PURPOSE To compare the ocular pulse amplitude (OPA) lowering effects of preservative-free tafluprost and dorzolamide-timolol fixed combination (DTFC) using dynamic contour tonometry. METHODS In total, 66 eyes of 66 patients with normal tension glaucoma (NTG) (n = 34) or primary open angle glaucoma (POAG) (n = 32) were included. Patients were divided into two groups: the preservative-free tafl...

Journal: :Archives of ophthalmology 2005
Christoph Kniestedt Shan Lin Joyce Choe Alan Bostrom Michelle Nee Robert L Stamper

OBJECTIVES To compare intraocular pressure readings of recently introduced dynamic contour tonometry (DCT) with pneumatonometry (PTG) and Goldmann applanation tonometry (GAT) and to correlate central corneal thickness (CCT) with these readings. DESIGN Prospective, cross-sectional observation and instrument validation study. We included 258 independent eyes with normal anterior segment examina...

2017
Kimihiro Igari Toshifumi Kudo Takahiro Toyofuku Yoshinori Inoue

We evaluated the endothelial function of patients with Buerger disease using peripheral arterial tonometry test, and examined the factors that are significantly correlated with the endothelial dysfunction in these patients. We performed the peripheral arterial tonometry test in 22 patients with Buerger disease. We recorded the patients' characteristics, including ankle brachial pressure index a...

2016
Gabriela González Castro Alastair D. Fitt John Sweeney

Ophthalmologists rely on a device known as the Goldmann applanation tonometer to make intraocular pressure (IOP) measurements. It measures the force required to press a flat disc against the cornea to produce a flattened circular region of known area. The IOP is deduced from this force using the Imbert-Fick principle. However, there is scant analytical justification for this analysis. We presen...

Journal: :Hypertension 2011
Thomas Weber Siegfried Wassertheurer Martin Rammer Edwin Maurer Bernhard Hametner Christopher C Mayer Johannes Kropf Bernd Eber

The prognostic value of central systolic blood pressure has been established recently. At present, its noninvasive assessment is limited by the need of dedicated equipment and trained operators. Moreover, ambulatory and home blood pressure monitoring of central pressures are not feasible. An algorithm enabling conventional automated oscillometric blood pressure monitors to assess central systol...

2015
Hiroyuki Ozawa Yorihisa Imanishi Fumihiro Ito Yoshihiro Watanabe Takashi Kato Hideo Nameki Kiyoshi Isobe Kaoru Ogawa Maria Kapritsou.

This study aimed to investigate the usefulness of intraluminal PCO2 (PiCO2) monitoring by air tonometry for the assessment of the vascular condition of the transferred jejunum after surgery for hypopharyngeal cancer.PiCO2 in the transplanted jejunum of 24 patients was monitored using air tonometry after radical surgery for hypopharyngeal cancer from 2003 to 2010.All but 1 patient, who removed t...

2011
Susan Gordon Wayne Melrose Jeffrey Warner Petra Buttner Leigh Ward

Lymphedema related to lymphatic filariasis (LF) is a disabling condition that commonly manifests in adolescence. Fifty-three adolescents, 25 LF infected and 28 LF non-infected, in age and sex-matched groups, using the Binax ICT rapid card test for filarial antigen were recruited to the study. None of the participants had overt signs of lymphedema. Lymphedema assessment measures were used to ass...

2011
Silvia Franco Andrade Daniel Silva Kupper Luiz Fernando Rodrigues de Pinho Elizabeth Cunha Franco Marcus Vinícius Felix Fabri Prataviera Rodrigo Rolim Duarte José Ricardo Cecílio Junqueira

The objective of this study was to evaluate and validate the accuracy of the Perkins handheld applanation tonometer for measuring intraocular pressure (IOP) in horses and cattle. Both eyes of 10 adult horses and cattle were evaluated in a postmortem study. The eyes from 10 clinically normal adult horses and cattle were also examined after bilateral auriculopalpebral nerve block and topical anes...

2007
James Brandt Felipe Medeiros

CORNEAL thickness may not only affect IOP measurements performed with Goldmann applanation tonometry (GAT) but may also be linked to the aetiology of glaucoma itself. However, there is no practical or reliable means at present to adjust IOP measurements in individual patients for variations in corneal thickness, James Brandt MD, professor of ophthalmology and director, glaucoma service, Univers...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید