نتایج جستجو برای: titanium implant

تعداد نتایج: 80029  

2011
Wirley Gonçalves Assunção Juliana Aparecida Delben Lucas Fernando Tabata Valentim Adelino Ricardo Barão Érica Alves Gomes

The passive fit between prosthesis and implant is a relevant factor for screw joint stability and treatment success. The aim of this study was to evaluate the influence of vertical misfit in abutment-implant interface on preload maintenance of retention screw of implant-supported crowns. The crowns were fabricated with different abutments and veneering materials and divided into 5 groups (n = 1...

Journal: :Acta odontologica latinoamericana : AOL 2009
Daniel G Olmedo Déborah R Tasat Gustavo Duffó Maria B Guglielmotti Rómulo L Cabrini

Pure titanium or titanium alloys, and to a lesser extent, zirconium, are metals that are often used in direct contact with host tissues. These metallic biomaterials are highly reactive, and on exposure to fluid media or air, quickly develop a layer of titanium dioxide (TiO2) or zirconium dioxide (ZrO2). This layer of dioxide forms a boundary at the interface between the biological medium and th...

2015
Pedro Paulo Cardoso Pita José Augusto Rodrigues Claudia Ota-Tsuzuki Tatiane Ferreira Miato Elton G. Zenobio Gabriela Giro Luciene C. Figueiredo Cristiane Gonçalves Sergio A. Gehrke Alessandra Cassoni Jamil Awad Shibli

The establishment of the subgingival microbiota is dependent on successive colonization of the implant surface by bacterial species. Different implant surface topographies could influence the bacterial adsorption and therefore jeopardize the implant survival. This study evaluated the biofilm formation capacity of five oral streptococci species on two titanium surface topographies. In vitro biof...

2017
Denghui Liu Chongru He Zhongtang Liu Weidong Xu

Titanium and titanium alloy are widely used as orthopedic implants for their favorable mechanical properties and satisfactory biocompatibility. The aim of the present study was to investigate the antibacterial effect and bone cell biocompatibility of a novel implant made with nanotubular anodized titanium coated with gentamicin (NTATi-G) through in vivo study in rabbits. The animals were divide...

Journal: :Journal of cell science 1992
B Groessner-Schreiber R S Tuan

Long-term stability of orthopaedic and dental implants depends on the integration of the artificial material into the surrounding bone tissue. The physical and chemical properties of implants, including those made of metals such as titanium, are thought to influence osseointegration. Despite the known importance of this interface, little is known about the factors that promote its formation. In...

Journal: :AJNR. American journal of neuroradiology 1997
W Wichmann K Von Ammon U Fink T Weik G M Yasargil

PURPOSE To evaluate the magnetic characteristics, artifact formation, and implant safety of titanium aneurysm clips for use in MR imaging. METHODS Aneurysm clips made of titanium alloy TiAl6V4 were tested in a magnetometer to determine their magnetic susceptibility and in a 1.5-T MR imager using both a geometric phantom and an animal model. A commercially available alpha-Phynox clip served as...

2004
Heidi Kuula

Purpose: Attachment of bacteria to titanium may differ not only between bacterial species but also between strains within a species. The aim of the present in vitro study was to examine differences in bacterial attachment using 4 gram-negative anaerobic species of bacteria that are considered potential periodontal pathogens. Materials and Methods: The attachment of clinical and laboratory strai...

2013
Wenjie Zhang Zihui Li Qingfeng Huang Ling Xu Jinhua Li Yuqin Jin Guifang Wang Xuanyong Liu Xinquan Jiang

BACKGROUND AND METHODS Various methods have been used to modify titanium implant surfaces with the aim of achieving better osseointegration. In this study, we fabricated a clustered nanorod structure on an acid-etched, microstructured titanium plate surface using hydrogen peroxide. We also evaluated biofunctionalization of the hybrid micro/nanorod topography on rat bone marrow mesenchymal stem ...

2008
C. N. Elias

Materials used for biomedical applications cover a wide spectrum and must exhibit specific properties. The most important property of materials used for fabricating implants is biocompatibility, followed by corrosion resistance. The main metallic biomaterials are stainless steels, cobalt alloy, and titanium and titanium alloys. Stainless steel was the first metallic biomaterial used successfull...

2015
Stefan Roehling Georges Ghazal Thomas Borer Florian Thieringer Michael Gahlert

Currently, titanium or specific titanium alloys are the most often used materials for the fabrication of dental implants. Many studies have confirmed the osseointegrative capacity and clinical long-term performance of moderately rough titanium implants. However, disadvantages have also been reported with regard to peri-implant infections and the titanium metal properties. Tooth colored ceramic ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید