2017
Hannah E. Bainbridge Martin J. Menten Martin F. Fast Simeon Nill Uwe Oelfke Fiona McDonald

PURPOSE This study investigates the feasibility and potential benefits of radiotherapy with a 1.5T MR-Linac for locally advanced non-small cell lung cancer (LA NSCLC) patients. MATERIAL AND METHODS Ten patients with LA NSCLC were retrospectively re-planned six times: three treatment plans were created according to a protocol for conventionally fractionated radiotherapy and three treatment pla...

2013
M. Zhang H. X. Deng D. Gu Q. Gu

Dalian Coherent Light Source (DCLS) will use a 300MeV LINAC to produce fully coherent photon pulses in the wavelength range between 150-50nm by high gain harmonic generation free electron laser (FEL) scheme [1]. Beam quality requirements for the linear accelerator (linac) are critical, including not only the beam brightness, but also the stability and the reliability. In this paper, optimizatio...

2004
E. Benedico Mora A. M. Lombardi E. Sargsyan M. Vretenar F. Gerigk

Linac4 is a normal conducting H_ linac proposed at CERN to provide a higher proton flux to the CERN accelerator chain. It should replace the existing Linac2 as injector for the PS booster (PSB). The same machine can also operate in the future as the front end of the SPL, a 2.2GeV superconducting linac with 1.8 mA average current. At present Linac4 consists of a Radio Frequency Quadrupole (RFQ),...

2000
O. Kester

The Radioactive Beam Experiment (REX-ISOLDE) [1,2] is a pilot experiment at ISOLDE (CERN) testing the new concept of post acceleration of radioactive ion beams by using charge breeding of the ions in a high charge state ion source and the efficient acceleration of the highly charged ions in a short LINAC using modern ion accelerator structures. In order to prepare the ions for the experiments s...

2000
Sanghyun Park

In light of the SPEAR3 upgrade project where the goal is to store up to 500 mA of beam current at 3.0 GeV beam energy, the injector RF gun and linac performance must be optimised in terms of reliability and injection rate. The basic linac system layout has not been changed for the last ten years of operation. A thermionic1.5-cell standing wave RF gun is the source of bunched beams at 10 Hz. An ...

Journal: :Acta chirurgica Belgica 2006
E Sebrechts

“Bruges possesses many treasures of art from previous centuries, but the living treasure of Bruges is certainly Professor Sebrechts” (). With these words, Queen Elisabeth honoured the surgeon with whom she had closely worked with the Belgian Red Cross (Fig. 1). A few weeks later, on Easter morning, March 28 1948, Joseph Sebrechts passed away due to bleeding oesophageal varicose veins, as a cons...

2009
E. Bravin

The measurement of the transverse beam emittance is essential in any particle accelerator. This paper describes the problems of transverse emittance measurement for the new H LINAC being built at CERN as a replacement of the existing proton LINAC.

1997
V. K. Bharadwaj K. Bane J. Clendenin P. Emma J. C. Sheppard M. D. Woodley

The Linac Coherent Light Source (LCLS) at SLAC is being designed to produce intense, coherent 0.15-nm x-rays. These x-rays will be produced by a single pass of a 15-GeV bunched electron beam through a long undulator. Nominally, the bunches have a charge of 1 nC, normalized transverse emittances of less than 1.5π mm-mr and an rms bunch length of 20 μm. The electron beam will be produced using th...

2012
K C Mittal

Electron accelerators from 500 keV to 10 MeV energy are employed for surface irradiation, food preservation, medical sterilization, cargo scanning and other industrial products. At EBC, a 10 MeV Linac has been indigenously developed and is operational for radiation processing. This is an on-axis coupled cavity standing wave type of RF linac operating with 50-70 keV electron gun having LaB6 cath...