نتایج جستجو برای: shaped aluminum cantilever beam

تعداد نتایج: 235254  

Journal: :The Review of scientific instruments 2011
John D Parkin Georg Hähner

Micro- and nanocantilevers are increasingly employed as mass sensors. Most studies consider the first flexural mode and adsorbed masses that are either discretely attached or homogeneously distributed along the entire length of the cantilever. We derive general expressions that allow for the determination of the total attached mass with any mass distribution along the cantilever length and all ...

2015
Wenping Jiang Daniel Bullen Abhijit Chandra Ranga Narayanaswami Frank Peters Kyle S. Jiang

Laser-based flexible fabrication (LBFF), a solid free form fabrication (SFF) method based on laser-cladding process, was developed as an alternative to conventional machining methods for producing dies and molds. LBFF is similar to processes such as LENS with additional features including shaped beam profile, quasi-coaxial powder delivery, and functionally graded materials. It uses a high-power...

Journal: :Scientific reports 2015
Rohit Sarkar Christian Rentenberger Jagannathan Rajagopalan

A critical assumption underlying in situ transmission electron microscopy studies is that the electron beam (e-beam) exposure does not fundamentally alter the intrinsic deformation behavior of the materials being probed. Here, we show that e-beam exposure causes increased dislocation activation and marked stress relaxation in aluminum and gold films spanning a range of thicknesses (80-400 nanom...

Journal: :Buildings 2023

The bridge of Shanghai Metro Line 10 over 6 is a U-shaped concrete single-box double-cell box beam continuous bridge. A novel method applied to construct the asymmetric cantilever prefabricated and assembled due limited construction space complex environment. Four mechanical state control methods are during T-shape structure process: tensioning pre-stressed steel strand, jacking by axial force ...

Journal: :The Review of scientific instruments 2007
A Hoffmann T Jungk E Soergel

Commercial atomic force microscopes usually use a position-sensitive photodiode to detect the motion of the cantilever via laser beam deflection. This readout technique makes it possible to measure bending and torsion of the cantilever separately. A slight angle between the orientation of the photodiode and the plane of the readout laser beam, however, causes false signals in both readout chann...

2002
Arun Majumdar

Recent experiments have shown that when specific biomolecular interactions are confined to one surface of a microcantilever beam, changes in intermolecular nanomechanical forces provide sufficient differential torque to bend the cantilever beam. This has been used to detect single base pair mismatches during DNA hybridization, as well as prostate specific antigen (PSA) at concentrations and con...

2014
R. S. Mohan A. Sarkar A. S. Sekhar

ABSTRACT Blade failure is a common problem of a steam turbine and it’s failure in-service results in safety risks, repair cost and non operational revenue losses. Thus, the reliability of these blades is very important for the successful operation of a steam turbine. Dynamic analysis of a steam turbine blade in computational environment is carried out in the present work. In order to gain physi...

2009
Eli S. Leland Christopher T. Sherman Peter Minor Paul K. Wright Richard M. White

A new type of MEMS sensor has been developed for measuring AC electric current. The sensor is comprised of a piezoelectric aluminum nitride MEMS cantilever with a microscale composite permanent magnet mounted to its free end. When placed in proximity to a wire carrying AC current, the alternating magnetic field surrounding the wire induces a sinusoidal force on the sensor magnet, deflecting the...

2007
W. Vance Payne Jon Geist

This report describes the development of a low cost, digital Micro Electro Mechanical System (MEMS) vibration meter that reports an approximation to the RMS acceleration of the vibration to which the vibration meter is subjected. The major mechanical element of this vibration meter is a cantilever beam, which is on the order of 500 µm in length, with a piezoresistor deposited at its base. Vibra...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید