نتایج جستجو برای: rotational alignment
تعداد نتایج: 107020 فیلتر نتایج به سال:
An aligned sample of HD(v = 1, J = 2, M(J) = 0) molecules is prepared under collision-free conditions using the S(0) stimulated Raman pumping transition. Subsequent coupling to the spins of the deuteron I(D) and the proton I(H) causes the initial degree of alignment to oscillate and decrease as monitored over the time range from 0-13 mus via the O2 line of the [2 + 1] REMPI E,F(1)Sigma-X(1)Sigm...
Neutron-rich Zr and Mo isotopes were populated as fission fragments produced by the 238Usa, fd fusionfission reaction. The level schemes of these nuclei have been extended beyond the first band crossing region, which can be ascribed to the h11/2 neutron pair alignment. The spin alignment and signature splitting for the nh11/2 orbitals in term of triaxiality is addressed. The crossing frequency ...
A synchrotron X-ray microscope is a powerful imaging apparatus for taking high-resolution and high-contrast X-ray images of nanoscale objects. A sufficient number of X-ray projection images from different angles is required for constructing 3D volume images of an object. Because a synchrotron light source is immobile, a rotational object holder is required for tomography. At a resolution of 10 ...
We present a new approach for computing planar hexagonal meshes that approximate given surface, represented as triangle mesh. Our method is based on two novel technical contributions. First, we introduce Coordinate Power Fields , which are pair of tangent vector fields the surface fulfill certain continuity constraint. prove fulfillment this constraint guarantees existence seamless parameteriza...
The alignment of molecules in the femtosecond laser field induces refractive index propagation medium to change, resulting spectral modulation effect. In this paper, time evolution wavelength offset a probe pulse under influence non-adiabatic molecular and Kerr effect is measured experimentally by pump-probe method nitrogen medium, degree N<sub>2</sub> obtained. By solving time-depe...
Background and purpose - There are many techniques for placing the femoral component in correct rotational alignment in total knee arthroplasty (TKA), but only a few have been tested against the supposed gold standard, rotation determined by postoperative computed tomography (CT). We evaluated the accuracy and variability of a new method, the clinical rotational axis (CRA) method, and assessed ...
The general ring laser operation model is adopted for the large gyroscopes C-II and G. An extended set of auxiliary sensors information is used for the long time period data modeling and ring laser behavior analysis with respect to the ideal case. Both instrumental errors and orientational effects are estimated and compensated where possible. The instrumental stability improved approximately fo...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید