نتایج جستجو برای: radiotherapy dose calculations

تعداد نتایج: 468780  

2015
Bei Liu Fritz A. Lerma Jianzhou Wu Byong Yong Yi Cedric Yu

Purpose: To improve the accuracy in megavoltage photon beam dose calculation in CBCT-based radiation treatment (RT) plans, using a kilovoltage cone-beam computed tomography (CBCT)-todensity-step (CBCT-SF) function. Materials and Methods: The CBCT-SF table is constructed from differential histograms of the voxel values of CBCT and Fan-beam CT (FBCT). From the CBCT histograms, frequency peaks rep...

پایان نامه :وزارت علوم، تحقیقات و فناوری - دانشگاه سیستان و بلوچستان 1390

abstract the influence of cation?? and anion?? interactions on the strength and nature of n…h hydrogen bond has been investigated by quantum chemical calculations in s-triazine…3hf complex. ab initio calculations were performed at mp2/6-311++g(d,p) level of theory. the natural bond orbital (nbo) analysis and the bader’s quantum theory of atoms in molecules (aim) were also used to elucidate t...

2017
Isaac C. F. Chang Jeff Chen Slav Yartsev

Helical tomotherapy with its advanced method of intensity-modulated radiation therapy delivery has been used clinically for over 20 years. The standard delivery quality assurance procedure to measure the accuracy of delivered radiation dose from each treatment plan to a phantom is time-consuming. RadCalc®, a radiotherapy dose verification software, has released specifically for beta testing a m...

2017
Konstantina Karava Stefanie Ehrbar Oliver Riesterer Johannes Roesch Stefan Glatz Stephan Klöck Matthias Guckenberger Stephanie Tanadini-Lang

BACKGROUND Radiotherapy for pancreatic cancer has two major challenges: (I) the tumor is adjacent to several critical organs and, (II) the mobility of both, the tumor and its surrounding organs at risk (OARs). A treatment planning study simulating stereotactic body radiation therapy (SBRT) for pancreatic tumors with both the internal target volume (ITV) concept and the tumor tracking approach w...

Azadeh Soleimani Elyas Sanaei Marjaneh Mir-Sadraee Mohammad Mohammadi, Mohammad Taghi Batiar,

Introduction: Rectal and bladder cancer are the most common disease among young man. Although External Radiotherapy (EBRT) is one of the most effective treatment options introduced so far, the testis undesired radiation dose increases the risk of infertility and hormonal malfunctioning. The testicles are usually outside of the radiation field, but they can be exposed either to ...

Journal: :EJNMMI Physics 2021

Abstract Background An individual dosimetry system is essential for the evaluation of precise doses in nuclear medicine. The purpose this study was to develop a calculating not only absorbed but also EQDX( α / β ) from PET-CT images patients targeted alpha therapy (TAT), considering dose dependence relative biological effectiveness, dose-rate effect, and heterogeneity. Methods A general-purpose...

A. Kazemian H. Gharaati H. Nedaie K. Zahedi

Introduction: Esophageal cancer is one of the most frequently occurring cancers in Iran and having a  high  incidence  rate  among  other  countries.  Radiotherapy  is  one  of  the  three  methods  (surgery,  radiotherapy and chemotherapy) for radical or palliative treatment of esophageal cancer. In this method  of treatment, the organs such as heart and spinal cord are regarded as organs at r...

آموزگار هاشمی, فرناز, حداد, پیمان, زاهدی, فاطمه, فرهان, فرشید, مهرداد, نیلی, کلاغچی, بیتا,

Background: Treatment of cervical carcinoma is routinely performed with Low Dose Rate (LDR) brachytherapy, but Brachytherapy in our department is done with Medium Dose Rate (MDR) due to the technical characteristics of the machine available here. Thus we decided to evaluate the results of this treatment in our department in a prospective study. Methods: Between March 2006 and July 2008, 140 pa...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید