نتایج جستجو برای: prosthesis failure
تعداد نتایج: 398030 فیلتر نتایج به سال:
A four month old infant was investigated for heart failure was found to have mitral incompetence and severe subvalvar aortic stenosis. The left ventricular outflow tract obstruction was found to be due to an anatomically anomalous mitral valve. The obstruction could only be relieved by removal of the mitral valve and its replacement with a St Jude's prosthesis. Two years after operation the chi...
We report a case of stem fracture of a collarless, polished, double-taper cemented stainless steel femoral prosthesis. Scanning electron microscopy showed fatigue striations, indicating failure by fatigue. This case study highlights that stem fracture can still occur with modern implants. Size 0 CPT stem should be avoided in patients with high body mass index. To our knowledge this is the first...
Transcutaneous aortic valve implantation has been established as an effective method for the treatment of highgrade stenosis in non-operative, high-risk conventional surgery patients. According to developed technologies, prostheses are divided into balloon-expandable (balloon-expandable valves, BEV) and self-expanding (self-expanding SEV). The two types devices have different models implantatio...
Isolated wear of the polyethylene tibial component led to failure in five of a series of 108 uncemented porous-coated knee replacements. The clinical features included pain, effusion and instability with progressive varus deformity. In all cases there was extensive wear on the medial side of the polyethylene surface of the prosthesis. The mechanism of such wear is complex, being due in part to ...
There is rare literature elaborating the complex total hip arthroplasty (THA) in patients with osteopetrosis who experienced malunion from femoral neck fracture. We have summarized the failure experience of the complex THA in osteopetrosis. Learned from the resurgery in the case reported by this paper, we recommend to highlight the initial stability of the prosthesis and not to overestimate the...
Oroantral communication (OAC) rarely occurs long after implant placement. The present report describes the rare etiology and the difficulty of the diagnosis of an uncommon OAC occurring 10 years after the implant placement in the posterior maxilla. The difficulty of the diagnosis lies in the absence of clinical symptoms of sinusitis and presence of multiunit prosthesis hiding implant failure. T...
A 37-year-old male with acute complicated methicillin-sensitive Staphylococcus aureus mitral valve endocarditis underwent urgent valve replacement with a bileaflet prosthesis. The postoperative course was complicated with fever and heart failure. Echocardiography showed a large subannular false aneurysm of the left ventricle. Three weeks later resection and closure of the defect with a patch ma...
Adverse reaction to metal debris (ARMD) in total hip arthroplasty surgery is a well-known problem. We present the case of a unipolar hemiarthroplasty requiring revision within 18 months of insertion secondary to an adverse reaction to metal debris. This case demonstrates a rare cause for failure of a hemiarthroplasty following a fragility fracture. We feel that ARMD should be considered in all ...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید