نتایج جستجو برای: photon dose distribution mcnp code percentage depth dose

تعداد نتایج: 1376868  

2011
B. Azadbakht

Background: The purpose of this study was to determine the percentage depth dose (PDD) of PAGAT normoxic polymer gel dosimeter by electron beams using MRI technique for a standard clinically used Co-60 therapy unit and an electa linear accelerator. Materials and Methods: Using MRI, the formulation to give the maximum change in the transverse relaxation rate R2(1/T2) was determined to be 4.5% N,...

2008
Vadim Chumak

Monte Carlo simulation (MCNP-4B code, ADAM phantom) was employed in order to estimate organ doses and doses to personal dosemeters of particular commercial design (one type of Harshaw dosemeter and two designs of RADOS dosemeters) in situations of irradiation of a person in photon radiation fields. For each photon energy and beam direction the partial conversion coefficients were calculated pro...

Journal: :Acta Radiologica: Therapy, Physics, Biology 1970

Journal: :Japanese Journal of Radiological Technology 2004

2006
Paola Caprile Carlos Daniel Venencia Pelayo Besa

We used the two available calculation algorithms of the Varian Eclipse 7.3 three-dimensional (3D) treatment planning system (TPS), the anisotropic analytic algorithm (AAA) and pencil-beam convolution (PBC), to compare measured and calculated two-dimensional enhanced dynamic wedge (2D EDW) dose distributions, plus implementation of the dynamic wedge into the TPS. Measurements were carried out fo...

One of the most common methods used in radiation therapy for the treatment of superficial skin lesions using the ortho-voltage radiation X (the kVp 300), respectively. One of the most important indicators for the treatment of this type of device, the quality of the X-ray output is usually half the thickness of the absorption (HVL) Vanrzhy show photons effective. However, in this study, the coef...

Introduction: Average glandular dose calculation in mammography with Mo-Rh target-filter and dose calculation for different situations is accurate and fast. Material and Methods: In this research, first of all, x-ray spectra of a Mo target bombarded by a 28 keV electron beam with and without a Rh filter were calculated using the MCNP code. Then, we used the Sobol-Wu parameters to write a FORTRA...

Journal: :journal of paramedical sciences 0
rouhollah adeli central iran research complex (yazd), nuclear science and technology research institute (nstri), iran. seyed pezhman shirmardi central iran research complex (yazd), nuclear science and technology research institute (nstri), iran. jamal amiri department of radiotherapy, faculty of paramedical sciences, kurdistan university of medical sciences, sanandaj, iran v.p. singh department of physics, karnataka university, dharwad 580003, india. m.e. medhat experimental nuclear physics departments, nuclear research centre, p.o.13759, cairo, egypt

monte carlo method is a very accurate method to optimize medical diagnostic radiology spectra and simulation of radiation transportation. using mcnp code, radiology and mammography attenuated x-rayspectraweresimulated.the ipem report number 78 was used as a reference to compare with the geant4 and mcnp simulations because of its popularity and wide availability. the results of geant4 in 40kev s...

Journal: :iranian journal of radiation research 0
a.s. meigooni university of kentucky medical center, department of radiation medicine, lexington, kentucky, usa u. malik h. zhang s.a. dini n. j. meigooni k. komanduri

background: an effective method for management of large and bulky malignant tumors. this treatment modality is also known as specially fractionated radiation therapy (sfrt). in this treatment technique a grid block converted the open radiation field into a series of pencil beams. dosimetric characteristics of an external beam grid radiation field have been investigated using experimental and mo...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید