نتایج جستجو برای: patients absorbed dose
تعداد نتایج: 2312589 فیلتر نتایج به سال:
The aim of this study was the investigation of absorbed dose to the kidneys, spleen, and liver during technetium-99 m ethylene dicysteine and technetium-99 m diethylenetriaminepentaacetic acid ((99m)Tc-EC and (99m)Tc-DTPA) kidney scan. Patients who had been prepared for the kidney scan, were divided into two groups (Groups 1 and 2). The first group (Group 1) and the second group (Group 2) recei...
Introduction: There are many ways to treat cancer and pain relief. One of the methods is radiopharmaceutical therapy. Indium 111-rituximab contains the radioisotope indium-111 and rituximab. The Indium-111, after decay, emits gamma rays with energies of 245 KeV and 171 KeV, and beta-radiation of 26 KeV. In this study, the absorbed dose of 111In-Rituximab in human body was calcu...
In the course of scanned carbon ion beam cancer treatment at GSI, 437 patients were successfully treated at sites that could be immobilized. With the upcoming facilities in Heidelberg, Marburg, and Kiel one major task is the expansion of the rasterscan technique [1] to moving tumors, e.g. lung cancer. This requires an extension of the treatment planning software TRiP [2] by 4D functionalities. ...
A car-borne survey was carried out in the northwestern, or Tokatsu, area of Chiba Prefecture, Japan, to make a detailed distribution map of absorbed dose rate in air four years after the Fukushima Daiichi Nuclear Power Plant accident. This area was chosen because it was the most heavily radionuclide contaminated part of Chiba Prefecture and it neighbors metropolitan Tokyo. Measurements were per...
The purpose of this study was to compare estimation of radiation absorbed doses to patients following bone scans with technetium-99m-labeled methylene diphosphonate (MDP) with the estimates given in MIRDose software. In this study, each patient was injected 25 mCi of (99m)Tc-MDP. Whole-body images from thirty patients were acquired by gamma camera at 10, 60, 90, 180 minutes after (99m)Tc-MDP in...
Background: Results are presented on some dosimetric characteristics of Sife – Eldeen dosimeter based on the radiation induced conductivity (RIC) of 3.5 M aqueous urea solutions. The studied characteristics were the response (RIC) of Sife – Eldeen dosimeter in broad ranges of absorbed dose, dose rates and at different irradiation temperature. Materials and Methods: Kent EIL5007 conductivity met...
The knowledge of the absorbed radiation dose is essential in order to interpret the results of animal experiments with chronic ingestion of radionuclides by rodents. In order to evaluate this absorbed dose, we applied the dose conversion factors proposed by ICRP publication 108 to mouse chronic ingestion experiments with 20 kBq.L-1 137Csor 90Sr-contaminated water. The results indicated that who...
introduction: during radiotherapy, high accuracy in the dose delivery is required because there is a strong relationship between the absorbed dose, local tumor control and particularly the normal tissue damage. in many institutions, in vivo dosimetry using diodes is performed to check the actual dose delivered. in general, the uncertainty in the dose delivered should fall within ± 5% of the...
Background and Objective: The most common intravascular brachytherapy sources include 32P, 188Re, 106Rh and 90Sr/90Y. In this research, skin absorbed dose for different covering materials in dealing with these sources were evaluated and the best covering material for skin protection and reduction of absorbed dose by radiation staff was recognized and recommended.Method: Four materials including...
Response and toxicity prediction is essential to rational implementation of cancer therapy. The biologic effects of radionuclide therapy are mediated via a well-defined physical quantity, the absorbed dose, which is defined as the energy absorbed per unit mass of tissue. The concepts, basic definitions, and different approaches to the clinical implementation of absorbed dose estimation are revi...