نتایج جستجو برای: ossicular fixation

تعداد نتایج: 53070  

Journal: :trauma monthly 0
mohammad hosein taraz-jamshidi orthopedic research center, shahid kamyab hospital, department of orthopedic surgery, mashhad university of medical sciences, mashhad, ir iran omid shapari orthopedic research center, shahid kamyab hospital, department of orthopedic surgery, mashhad university of medical sciences, mashhad, ir iran reza shiravani orthopedic research center, shahid kamyab hospital, department of orthopedic surgery, mashhad university of medical sciences, mashhad, ir iran saeed moalemi orthopedic research center, shahid kamyab hospital, department of orthopedic surgery, mashhad university of medical sciences, mashhad, ir iran ali birjandinejad orthopedic research center, shahid kamyab hospital, department of orthopedic surgery, mashhad university of medical sciences, mashhad, ir iran; orthopedic research center, shahid kamyab hospital, department of orthopedic surgery, mashhad university of medical sciences, fadaieiane eslam st., 9166637477 mashhad, ir iran. tel.: +98-5118518853, fax: +98-5118549234

introduction fracture - dislocations of the talus are typically due to high energy injuries. displaced fracture - dislocations of the talus have poor outcomes in general and complications are common. although talar fracture is common and comprises the second most common tarsal fracture, bilateral fracture - dislocations of the talus are rare. not many reports regarding the subject can be found ...

Journal: :journal of dentistry, tehran university of medical sciences 0
h. mohajerani assistant professor, department of oral and maxillofacial surgery, school of dentistry, shahid behes m. mehdizadeh oral & maxillofacial surgeon, private practice a. khalighi sigaroodi postgraduate student, department of oral and maxillofacial surgery, school of dentistry, shahid behe

objective: the aim of this study was to assess skeletal relapse in patients who underwent mandibular setback by bilateral sagittal split ramus osteotomy (bssro) and osteosynthesis wiring techniques. materials and methods: in this semi-experimental study, 10 patients (8 women, 2 men) with 3-8 millimeters overjet underwent mandibular setback with bssro, osteosynthesis wiring and inter maxillary f...

Journal: :Annals of International medical and Dental Research 2018

Journal: :trauma monthly 0
mohammad fakoor imam khomeini hospital, ahvaz jundishapur university of medical sciences, ahvaz, ir iran; imam khomeini hospital, ahvaz jundishapur university of medical sciences, ahvaz, ir iran. tel: +98-9161186420, fax: +98-6132921836 morteza fakoor imam khomeini hospital, ahvaz jundishapur university of medical sciences, ahvaz, ir iran payam mohammadhoseini imam khomeini hospital, ahvaz jundishapur university of medical sciences, ahvaz, ir iran

background distal radius fracture is common in all ages. mobility and wrist function is important. the choice of treatment should aim for optimal function with minimal complications. objectives in this study we compared two surgical approaches, open reduction and internal fixation (orif) and closed reduction with external fixation (cr + ef), for treatment of intra-articular distal radius fractu...

Journal: :Thorax 1970
D B Clarke M C Neligan

In nine dogs submitted to a severe myocardial ischaemic challenge, multiple prosthetic implants running from the descending aorta to myocardial tunnels were successful in sustaining effective ventricular contraction for a mean period of 27 minutes. A control series of five dogs and five animals, in which the prostheses clotted, developed ventricular fibrillation within six minutes of the ligati...

2010
Justus F Ilgner Slavomir Biedron Elena Fadeeva Boris Cichkov Doris Klee Anneke Loos Eveline Sowa-Soehle Martin Westhofen

Introduction Titanium implants can be regarded as the current gold standard for restoration of sound transmission in the middle ear following destruction of the ossicular chain by chronic inflammation. Many efforts have been made to improve prosthesis design, while less attention had been given to the role of the interface. We present a study on chemical nanocoating on microstructured titanium ...

A. Arunyanark A. Patanothai, C. Akkasaeng C.C. Holbrook N. Vorasoot S. Jogloy, S. Pimratch S. Wongkaew T. Kesmala

Traits related to nitrogen fixation may be used as indirect selection criteria foraflatoxin resistance in peanut. The aim of this study was to investigate therelationship between N2 fixation traits and aflatoxin contamination in peanut underdifferent drought conditions. Eleven peanut genotypes were evaluated under threewater regimes for two seasons in the field. Data were observed on kernel inf...

Journal: :Journal of the Royal Society of Medicine 1995
G A Manley

Due to the simplicity of their manufacture and placement, middle-ear prostheses are generally constructed using only a single 'ossicle'. The variety of pathologies frequently make it necessary to devise individual solutions and the results are often unsatisfactory. Many methods of improving the prostheses have been tried, with very mixed results. Even until recently, the fundamental assumptions...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید