نتایج جستجو برای: optical saturation

تعداد نتایج: 313547  

Journal: :Optics letters 2013
Jun Xia Amos Danielli Yan Liu Lidai Wang Konstantin Maslov Lihong V Wang

Photoacoustic tomography (PAT) is a hybrid imaging technique that has broad preclinical and clinical applications. Based on the photoacoustic effect, PAT directly measures specific optical absorption, which is the product of the tissue-intrinsic optical absorption coefficient and the local optical fluence. Therefore, quantitative PAT, such as absolute oxygen saturation (sO₂) quantification, req...

Journal: :Applied optics 2002
Erica L Heffer Sergio Fantini

We present a noninvasive optical method to measure the oxygen saturation of hemoglobin in breast lesions. This method introduces the novel concept that the best choice of near-infrared wavelengths for noninvasive tumor oximetry consists of a wavelength pair (lambda1, lambda2) within the range 680-880 nm, where the specific values of lambda1 and lambda2 depend on the optical properties of the sp...

1991
Alan L. Migdall Carsten Winnewisser

The effect of optical irradiance on the linearity of a Si photodiode was studied. These results are compared for light modulated at 30 MHz and at dc as the optical irradiance was varied over a 9 decade range. We discuss how these results affect the use of this detector as a heterodyne receiver. As the optical irradiance varied from 10-2 to 10+3 mW/cm2, while maintaining constant total power, th...

Journal: :Journal of biomedical optics 2003
Sonnia Maria Lopez Silva Maria Luisa Dotor Castilla Juan Pedro Silveira Martin

Pulse oximeters are widely used for noninvasive monitoring of oxygen saturation in arterial blood hemoglobin. We present a transmittance pulse oximetry system based on near-infrared (NIR) laser diodes (750 and 850 nm) for monitoring oxygen saturation of arterial blood hemoglobin. The pulse oximetry system is made up of the optical sensor, sensor electronics, and processing block. Also, we show ...

2015
Yingzhi Wang Dong Pu Jia Yang Tailin Han

Heart rate and bloody oxygen saturation are significant human's health parameters. This design is a mouse pad monitoring heart rate and oxygen saturation, to reduce the risk of undetected heart state change after concentrating on computer for a long time. Optical power signals reflected by blood are collected by reflective photoelectric sensor, NJL5501R, and then through filtering and amplifica...

Journal: :Optics letters 2014
Guillaume Point Yi Liu Yohann Brelet Sergey Mitryukovskiy Pengji Ding Aurélien Houard André Mysyrowicz

We report on the lasing action of atmospheric air pumped by an 800 nm femtosecond laser pulse with peak power up to 4 TW. Lasing emission at 428 nm increases rapidly over a small range of pump laser power, followed by saturation above ∼1.5  TW. The maximum lasing pulse energy is measured at 2.6 μJ corresponding to an emission power in the MW range, while a maximum conversion efficiency of 3.5×1...

Journal: :IEICE Transactions 2008
Satoshi Narikawa Hiroaki Sanjoh Naoya Sakurai Kiyomi Kumozaki

We describe the transmission characteristics of a wavelength independent wavelength division multiplexing passive optical network (WDM-PON) based on a wavelength channel data rewriter (WCDR). The WCDR is composed of a linear amplifier (LA) and a saturated semiconductor optical amplifier (SOA), and by using the WCDR in optical network units (ONUs), we can erase the downstream signal and modulate...

Journal: :Journal of vision 2011
Franz Faul Vebjørn Ekroll

In F. Faul and V. Ekroll (2002), we proposed a filter model of perceptual transparency that describes typical color changes caused by optical filters and accurately predicts perceived transparency. Here, we provide a more elaborate analysis of this model: (A) We address the question of how the model parameters can be estimated in a robust way. (B) We show that the parameters of the original mod...

2009
Yoichi Murakami Junichiro Kono

Through an investigation of photoemission properties of highly photoexcited single-walled carbon nanotubes, we demonstrate that there is an upper limit on the achievable excitonic density. As the intensity of optical excitation increases, all photoluminescence emission peaks arising from different chirality singlewalled carbon nanotubes showed clear saturation in intensity. Each peak exhibited ...

2016
Justin P. Phillips Richard M. Langford Serene H. Chang Kishore Maney Panayiotis A. Kyriacou Deric P. Jones

This pilot investigation was undertaken to assess the performance of a novel fiber-optic cerebral pulse oximetry system. A fiber-optic probe designed to pass through the lumen of a cranial bolt of the type used to make intracranial pressure measurements was used to obtain optical reflectance signals directly from the brain tissue. Preliminary results from seven patients measured in the operatin...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید